EMC China Lab

EN 60529 Enclosure Protection Rating Testing

Views :
Update time : 2026-11-26

Standard Full Name: Degrees of protection provided by enclosures (IP Code)

Current Version: EN 60529:1991+A1:2000+A2:2013 (identical to iec 60529:1989+A1:1999+A2:2013)

Core Positioning: A general foundational protection standard for EU CE certification (LVD, RED, and other directives). It specifies the classification of degrees of protection, test methods, and acceptance criteria for electrical equipment enclosures against access by personnel, ingress of solid foreign objects, and ingress of water; applicable to electrical enclosures with a rated voltage of ≤ 72.5 kV.


IP Code Structure

IP [First Characteristic Numeral / X] [Second Characteristic Numeral / X] [Additional Letter A/B/C/D] [Supplementary Letter H/M/S/W]

1.X: No protection test is performed for this position (e.g., IPX7: no dust test, only Level 7 waterproof test).

2.Additional Letters (A/B/C/D): Additional protection against access to hazardous parts by personnel; used only when the actual protection is higher than that indicated by the first characteristic numeral.

3.Supplementary Letters (H/M/S/W): Description of test conditions and equipment attributes.


Additional Letters (Personnel Protection)

Letter

Protection Meaning

A

Protection against access to hazardous parts with the back of the hand

B

Protection against access to hazardous parts with a test finger

C

Protection against access to hazardous parts with a 2.5 mm tool

D

Protection against access to hazardous parts with a 1.0 mm wire


Supplementary Letters

H: High-voltage apparatus

M: Movable parts of the equipment are in motion during the water test

S: Equipment is stationary during the water test

W: Suitable for use under specified outdoor weather conditions (equipped with additional weather protection)


First Characteristic Numeral: Protection Against Solid Foreign Objects and Access (0–6)

Numeral

Protection Definition

Brief Test Description

0

Non-protected

No test

1

Protected against solid foreign objects ≥ 50 mm, and back of the hand

Ø50 mm test sphere shall not fully penetrate the enclosure

2

Protected against solid foreign objects ≥ 12.5 mm, and fingers

Ø12.5 mm test sphere, jointed test finger

3

Protected against solid foreign objects ≥ 2.5 mm, and tools

Ø2.5 mm steel rod, 3 N thrust

4

Protected against solid foreign objects ≥ 1.0 mm, and thin wires

Ø1.0 mm steel wire, 1 N thrust

5

Dust-protected (limited ingress of dust)

Dust chamber test; a small amount of dust ingress is permitted, provided it does not affect safety or normal operation

6

Dust-tight (complete protection against dust)

Dust chamber negative pressure test; no ingress of dust into the enclosure


Second Characteristic Numeral: Protection Against Water (0–9)

Numeral

Protection Definition

Typical Test Conditions

0

Non-protected

No test

1

Vertically falling water drops

Drip device, 10 min

2

Vertically falling water drops when tilted at 15°

Enclosure tilted 15° (front, back, left, and right), dripping for 10 min

3

Spraying water (≤ 60° from vertical)

Oscillating tube spray, 10 min

4

Splashing water from all directions

Oscillating tube spray / splash nozzle, 10 min

5

Low-pressure water jets

6.3 mm nozzle, flow rate 12.5 L/min, distance 2.5–3 m, 3 min

6

Powerful water jets / heavy seas

12.5 mm nozzle, flow rate 100 L/min, distance 2.5–3 m, 3 min

7

Temporary immersion in water

1 m water depth, immersion for 30 min; ingress of water shall not be harmful

8

Continuous immersion in water

Water depth and duration agreed upon by the manufacturer, deeper and longer than IPX7

9

80°C high-pressure hot water jets (IPX9)

Water temperature 80°C, pressure 8–10 MPa, flow rate 14–16 L/min; sprayed at 4 angles for 30 s each, sample turntable at 5 rpm; suitable for high-pressure washdown scenarios (food machinery, sanitation vehicles)

Note: The particularity of IPX8 needs to be emphasized separately.

The standard itself does not specify a uniform water depth and duration for IPX8. The commonly seen "2 meters, 1 hour" is merely a conventional practice adopted by some manufacturers or testing laboratories, not a mandatory value in the standard. The continuous immersion conditions for IPX8 (depth, duration, and pressure cycling method) should be negotiated and determined by both the supplier and the buyer based on the product's actual usage scenario, and documented in the technical files.


General Test Prerequisites

1.Environmental Conditions: 15–35°C, relative humidity 25%–75%, atmospheric pressure 86–106 kPa.

2.Test Sample: Tested in its as-delivered condition and normal installation position; sealing rings, cover plates, and cable entries must all be assembled as in actual use.

3.General Rule: Claiming a specific rating implies compliance with all lower ratings by default.

4.Test Medium: Clean water; otherwise specified if the product standard has special requirements.

5.Sample Status: Whether the sample is energized or operating is determined by the product specification or the supplementary letters M/S.


EN 60529 Testing Process

1.Communicate product information and confirm the testing standards and test conditions.

2.Fill out the application form and provide samples.

3.The laboratory conducts testing in accordance with standard requirements or specified test conditions.

4.Upon passing the test, the test report is issued.


Testing Lead Time: 5–7 working days.

JJR Lab (CNAS and CMA accredited laboratory) provides EN 60529 enclosure IP protection rating testing services.



Email:hello@jjrlab.com


Leave Your Message


Write your message here and send it to us


Related News
Read More >>
What is EN IEC 60335-2-81 Certification Testing? What is EN IEC 60335-2-81 Certification Testing?
11 .26.2026
Get EN IEC 60335-2-81 testing for foot warmers & heating mats at JJR LAB. Our ISO/IEC 17025, CNA...
EN 60529 Enclosure Protection Rating Testing EN 60529 Enclosure Protection Rating Testing
11 .26.2026
EN 60529 enclosure IP protection rating testing at JJR Lab. CNAS, CMA, A2LA & ISO/IEC 17025 accr...
EN 301 489-1 V2.2.3 Radio Equipment Compliance Sta EN 301 489-1 V2.2.3 Radio Equipment Compliance Sta
11 .26.2026
EN 301 489-1 V2.2.3 radio equipment EMC testing by JJR Lab. ISO/IEC 17025, CNAS, CMA & A2LA accr...
Amazon Squishy Toy VOC Compliance and DV Verificat Amazon Squishy Toy VOC Compliance and DV Verificat
11 .26.2026
Amazon squishy toy VOC compliance & DPV verification by JJR Lab. Accredited by CMA, CNAS, A2LA &...
How to get a 16 CFR Part 1501 Test Report? How to get a 16 CFR Part 1501 Test Report?
11 .25.2026
Get your 16 CFR Part 1501 test report at China JJR Laboratory. ISO/IEC 17025, A2LA, CMA & CNAS a...
What Is ASTM F2670-2022 Certification Compliance? What Is ASTM F2670-2022 Certification Compliance?
11 .25.2026
Get ASTM F2670-2022 compliance for infant bath tubs at JJR Lab. Our CMA, CNAS, A2LA & ISO/IEC 17...
Amazon Canada Home Playground Equipment Compliance Amazon Canada Home Playground Equipment Compliance
11 .25.2026
Ensure Amazon Canada home playground equipment compliance with JJR Lab. ISO/IEC 17025, CMA, CNAS &am...
Mobile Phone and Tablet 4G Testing Mobile Phone and Tablet 4G Testing
11 .24.2026
JJR Lab offers 2027 4G LTE testing & certification for mobile phones and tablets. Accredited by ...

Leave Your Message