Standard Full Name: Degrees of protection provided by enclosures (IP Code)
Current Version: EN 60529:1991+A1:2000+A2:2013 (identical to iec 60529:1989+A1:1999+A2:2013)
Core Positioning: A general foundational protection standard for EU CE certification (LVD, RED, and other directives). It specifies the classification of degrees of protection, test methods, and acceptance criteria for electrical equipment enclosures against access by personnel, ingress of solid foreign objects, and ingress of water; applicable to electrical enclosures with a rated voltage of ≤ 72.5 kV.
IP [First Characteristic Numeral / X] [Second Characteristic Numeral / X] [Additional Letter A/B/C/D] [Supplementary Letter H/M/S/W]
1.X: No protection test is performed for this position (e.g., IPX7: no dust test, only Level 7 waterproof test).
2.Additional Letters (A/B/C/D): Additional protection against access to hazardous parts by personnel; used only when the actual protection is higher than that indicated by the first characteristic numeral.
3.Supplementary Letters (H/M/S/W): Description of test conditions and equipment attributes.
H: High-voltage apparatus
M: Movable parts of the equipment are in motion during the water test
S: Equipment is stationary during the water test
W: Suitable for use under specified outdoor weather conditions (equipped with additional weather protection)
Note: The particularity of IPX8 needs to be emphasized separately.
The standard itself does not specify a uniform water depth and duration for IPX8. The commonly seen "2 meters, 1 hour" is merely a conventional practice adopted by some manufacturers or testing laboratories, not a mandatory value in the standard. The continuous immersion conditions for IPX8 (depth, duration, and pressure cycling method) should be negotiated and determined by both the supplier and the buyer based on the product's actual usage scenario, and documented in the technical files.
1.Environmental Conditions: 15–35°C, relative humidity 25%–75%, atmospheric pressure 86–106 kPa.
2.Test Sample: Tested in its as-delivered condition and normal installation position; sealing rings, cover plates, and cable entries must all be assembled as in actual use.
3.General Rule: Claiming a specific rating implies compliance with all lower ratings by default.
4.Test Medium: Clean water; otherwise specified if the product standard has special requirements.
5.Sample Status: Whether the sample is energized or operating is determined by the product specification or the supplementary letters M/S.
1.Communicate product information and confirm the testing standards and test conditions.
2.Fill out the application form and provide samples.
3.The laboratory conducts testing in accordance with standard requirements or specified test conditions.
4.Upon passing the test, the test report is issued.
Testing Lead Time: 5–7 working days.
JJR Lab (CNAS and CMA accredited laboratory) provides EN 60529 enclosure IP protection rating testing services.
What is EN IEC 60335-2-81 Certification Testing?
EN 60529 Enclosure Protection Rating Testing
EN 301 489-1 V2.2.3 Radio Equipment Compliance Sta
Amazon Squishy Toy VOC Compliance and DV Verificat
How to get a 16 CFR Part 1501 Test Report?
What Is ASTM F2670-2022 Certification Compliance?
Amazon Canada Home Playground Equipment Compliance
Mobile Phone and Tablet 4G Testing
24-hour online customer service at any time to respond, so that you worry!