The cross-cut test, also known as the adhesion test, is an important test method commonly used to evaluate the surface adhesion of paints, varnishes, conversion materials, metal coatings, coatings and related products on steel plates, and is used to grade the adhesion test results.

What is ASTM D3359 Certification Test(图1)


Cross-Cut Test

Applicable to adhesive coatings with surface coating thicknesses of 0~50μm and 50μm–125μm.

Coating Thickness

Spacing Between Cuts

Number of Cuts

0~50μm

1mm

11

50μm–125μm

2mm

6

Common Equipment for Cross-Cut Test

Cross-cut cutter

Cross-Cut Spacing

1mm × 1mm or 2mm × 2mm

Special Adhesive Tapes for Cross-Cut Test

3M 600 & 610, Nichiban Tape, P99 Tape

Cross-Cut Test Methods and Common Standards

• ASTM D3359-09 Standard Test Methods for Measuring Adhesion by Tape Test

• BS 3900-E6 Paints and varnishes — Methods of test — Part E6: Cross-cut test

• ISO 2409 Paints and varnishes — Cross-cut test

• DIN 53151 Testing of rubber; Determination of tear strength

Adhesion Test Evaluation Standards

• ISO Grade 0, ASTM Grade 5B: The edges of the cuts are completely smooth with no flaking at the grid edges.

• ISO Grade 1, ASTM Grade 4B: Small flakes at the intersections of the cuts; actual damage within the grid area does not exceed 5%.

• ISO Grade 2, ASTM Grade 3B: Flaking at the edges and intersections of the cuts, covering 5%–15% of the area.

• ISO Grade 3, ASTM Grade 2B: Flaking along the cut edges, large partial flaking, or even entire flaking of some grids; flaked area accounts for 15%–35%.

• ISO Grade 4, ASTM Grade 1B: Large flaking along the cut edges, complete flaking of some grids; flaked area accounts for 35%–65%.

• ISO Grade 5, ASTM Grade 0B: Exceeds the previous grade.

Why Choose Us

JJR LAB complies with the ISO/IEC 17025 management guidelines, is accredited by CNAS and qualified with CMA. We issue impartial, independent and authoritative third-party test reports that are recognized worldwide.


Email:hello@jjrlab.com


Leave Your Message


Write your message here and send it to us


Related News
Read More >>
ROHS and Weee Compliance ROHS and Weee Compliance
05 .12.2026
RoHS and WEEE directives control hazardous substances and e-waste; JJR LAB offers third-party testin...
Waste of Electrical and Electronic Equipment Weee Waste of Electrical and Electronic Equipment Weee
05 .12.2026
WEEE EU EPR: producers register, fund recycling, label, report across member states. JJR LAB incl fe...
Low Voltage Directive CE Marking Low Voltage Directive CE Marking
05 .12.2026
LVD CE Marking covers EU safety for 50–1000VAC/75–1500VDC products. JJR LAB provides testing & c...
What are CE EMC Testing Requirements What are CE EMC Testing Requirements
05 .12.2026
CE EMC testing ensures EU compliance (EN 55032/55035/61000, RED). JJR LAB offers EMI/EMS, ESD, surge...
What are the CE EMC standards What are the CE EMC standards
05 .12.2026
CE EMC standards ensure EU devices meet emission and immunity rules. JJR LAB provides EN 55032/55035...
RF Testing Companies RF Testing Companies
05 .11.2026
RF Testing Companies EU third-party labs ensure wireless compliance via FCC/CE EMC EMI SAR OTA tests...
European WEEE Directive European WEEE Directive
05 .11.2026
EU WEEE 2012/19/EU: producers register, label, report, finance e-waste recycling (15 categories EPR)...
European Authorised Representative European Authorised Representative
05 .11.2026
EU Authorised Representative (EU AR) is EU compliance agent for non-EU medical devices under MDR/IVD...

Leave Your Message