EMC China Lab

Electric Bicycle FCC Certification Testing

Views :
Update time : 2024-04-22

For electric bicycles exported to the US market, FCC certification is essential and regarded as the passport for manufacturers to enter the US market. Attention all electric bicycle export businesses: Here's your guide to understanding the fcc electromagnetic compatibility certification testing standards for electric bicycles in the US market.

 

Electric Bicycle FCC Certification Testing(图1)


fcc sdoc - Supplier’s Declaration of Conformity (sdoc) – (Unintentional Radiator)

fcc part 15B – Unintentional Radiator

- 15.107 Conducted Emission

  - The lower limit applies at the band edges

  - Lower limits apply at band edges.

 

- 15.109 Radiated Emission

  - The field strength of radiated emissions from unintentional radiators at a distance of 3 meters shall not exceed the following values.

  - The field strength of radiated emissions from unintentional radiators at a distance of 3 meters should not exceed the specified values. Bluetooth functionality must meet the following requirements.

 

fcc id-Certification –(Intentional Radiator)

- 15.247-Operation within the bands 2400-2483.5MHz

  - Bluetooth EDR Mode Testing Items

    - Max. Output power

    - 20dB Bandwidth

    - Channel Separation

    - Channel Number

    - Dwell Time

    - Out of Band Antenna Conducted Emission

    - Radiated Emission

    - Radiated Spurious Emission

    - Band Edge

    - AC Conducted Emission

  - Bluetooth BLE Mode Testing Items

    - Max. Output power

    - 6 dB Bandwidth

    - Power Density

    - Out of Band Antenna Conducted Emission

    - Radiated Emission

    - Radiated Spurious Emission

    - Band Edge

    - AC Conducted Emission

 Electric Bicycle FCC Certification Testing(图2)

  Note: If Bluetooth supports dual mode (EDR+BLE), it needs to meet the requirements for both simultaneously.

 

  Alternatively, 15.249 – Operation within the bands 2400-2483.5MHz can be used.

 

  - Max. Output power

  - Transmitter Radiated Emission

  - Band Edge

  - 20dB Bandwidth

  - AC Conducted Emission

 

  Note: All relevant circuits for electric assisted bicycles must collectively meet the above FCC requirements, including lighting, instrument control panels, wireless components, etc.


Email:hello@jjrlab.com


Leave Your Message


Write your message here and send it to us


Related News
Read More >>
ISO 10993-10 In Vitro Skin Sensitization Test Serv ISO 10993-10 In Vitro Skin Sensitization Test Serv
04 .11.2026
In vitro skin sensitization tests assess allergic risks for safety use. JJR LAB offers ISO 10993-10 ...
What is ISO 10993 Biocompatibility Testing? What is ISO 10993 Biocompatibility Testing?
04 .11.2026
JJR is a CNAS- and ISO/IEC 17025-accredited Laboratory providing ISO 10993 compliance testing. Repor...
How to Perform a Valid CCK-8 Cytotoxicity Assay How to Perform a Valid CCK-8 Cytotoxicity Assay
04 .10.2026
A valid CCK-8 cytotoxicity assay uses WST-8 to assess cell viability via color change, with key step...
Introduction to Cytotoxicity Assay (CCK-8 Method) Introduction to Cytotoxicity Assay (CCK-8 Method)
04 .10.2026
CCK-8 assay measures viable cells via WST-8 conversion, enabling rapid, sensitive detection for drug...
What Are the Cytotoxicity Assay Methods? What Are the Cytotoxicity Assay Methods?
04 .10.2026
Cytotoxicity assays reveal cell safety by measuring viability or damage. JJR LAB outlines methods li...
What is Ingress Protection (IP) Testing and Standa What is Ingress Protection (IP) Testing and Standa
04 .08.2026
Ingress Protection (IP) defines enclosure resistance to dust and water per IEC 60529; JJR LAB verifi...
What is UL 153 Lighting Standards and Portable Lum What is UL 153 Lighting Standards and Portable Lum
04 .08.2026
UL 153 defines safety rules for portable luminaires; Amazon requires compliant testing. JJR verifies...
What is Conducted and Radiated Emissions Testing? What is Conducted and Radiated Emissions Testing?
04 .08.2026
EMC ensures EMI control & immunity; conducted (150 kHz–30 MHz) and radiated (30 MHz–6 GHz) tests...

Leave Your Message