EMC China Lab

EMC Accredited Test Labs in Ukraine

Views :
Update time : 2024-05-08

We understand that you are looking for an EMC (Electro Magnetic Compatibility) testing laboratory in Ukraine. However, we still want to help you understand us; because compaRED to local Australian laboratories, we can save you 30% on testing and certification costs.

 

JJRLAB is a Chinese EMC electromagnetic compatibility testing laboratory; we are an ISO/IEC 17025 and GLP laboratory. Welcome to learn more about us.

EMC Accredited Test Labs in Ukraine(图1)

JJRLAB has established a comprehensive independent testing system, consisting of four standard 3-meter anechoic chambers, one RF fULl-wave anechoic chamber, one set of RS test systems, three interference testing rooms, and four shielded rooms. The testing instruments are advanced and manufactured and constructed by well-known international companies in the industry such as Germany's Rohde & Schwarz, TESEQ, Schwarzbeck, Switzerland's EMTEST, HAEFELY, EMC Partner, America's Agilent, FCC, and others. The technical team is composed of a group of professionals and expert consultants with many years of experience in emc testing, countermeasures, and certification work, capable of providing one-stop services for electronic enterprises from PCB layout design, circuit parameter calculation, component specification selection to complete system integration, product testing, countermeasures, and certification.

 

EMC Testing Products:

◆ Automotive Electronic EMC

◆ Aerospace Electronic EMC

◆ Rail Transportation Electronic EMC

◆ Consumer Electronics EMC

 

EMC Testing Projects:

EMI (Electromagnetic Interference) Testing Projects

➢ Radiated Emissions (RE) Testing

➢ Conducted Emissions (CE) Testing

➢ Disturbance Power Testing

➢ Harmonic Current Testing

➢ Voltage Fluctuation Testing

EMS (Electromagnetic Susceptibility) Testing Projects

➢ Electrostatic Discharge (ESD) Testing

➢ Radiofrequency Electromagnetic Field Immunity (RI) Testing

➢ Electrical Fast Transient Burst Immunity (EFT) Testing

➢ Surge (Lightning & Surges) Immunity Testing

➢ Radiofrequency Field Induced Conducted Immunity (CI) Testing

➢ Power Frequency Magnetic Field Immunity (PFMI) Testing

➢ Voltage Dips, Short Interruptions, Voltage Variation Immunity (DIPS) Testing

 

emc certification:

Europe: CE-EMC, E-Mark

North and South America: FCC, ised, IC

Asia: VCCI, bsmi, CCC, CQC, MSIP, PSE, SIRIM, TISI, ISI

Australia and Africa: RCM, SABS

 

EMC Testing Standards (Partial):

Automotive Electronic EMC

GB/T 17619 "Electromagnetic Radiation Susceptibility Limits and Measurement Methods for Automotive Electronic Components"

ISO 7637-1/-2/-3, GB/T 21437.1/.2/.3 "Electrical Disturbances Caused by Conduction and Coupling in Road Vehicles"

ISO 10605 "Test Methods for Electrical Disturbances from Electrostatic Discharge in Road Vehicles"

GB/T 19951 "Test Methods for Electrical Disturbances from Electrostatic Discharge in Road Vehicles"

GB/T 28046.2 "Environmental Conditions and Tests for Electrical and Electronic Equipment for Road Vehicles - Part 2: Electrical Loads"

ISO 16750-2 "Environmental Conditions and Tests for Electrical and Electronic Equipment for Road Vehicles - Part 2: Electrical Loads"

ISO 21848 "Electrical Loads of 42V Power Supply Voltage for Road Vehicles"

ISO 11452-1/-2/-3/-4/-5/-7/-8/-9/-10/-11 "Electromagnetic Disturbance Resistance Test Methods for Electrical/Electronic Components of Road Vehicles to Narrowband Radiated Electromagnetic Energy"

GB/T 18655 "Limits and Measurement Methods for Radio Disturbance Characteristics for Vehicles, Boats, and Internal Combustion Engines to Protect On-Board Receivers"

CISPR 25 "Limits and Measurement Methods for Radio Disturbance Characteristics of Vehicles, Boats, and Internal Combustion Engines to Protect On-Board Receivers"

 

Consumer Electronics EMC

IEC 61547/GB T 18595 "Electromagnetic Compatibility Immunity Requirements for General Lighting Equipment"

CISPR 15/GB 17743 "Limits and Measurement Methods for Radio Disturbance Characteristics of Electrical Lighting and Similar Equipment"

IEC 61000-3-2 "Electromagnetic Compatibility - Limits - Harmonic Current Emission Limits (Equipment with Input Current ≤16A per Phase)"

GB 17625.1 "Electromagnetic Compatibility - Limits - Harmonic Current Emission Limits (Equipment with Input Current ≤16A per Phase)"

IEC 61000-3-3 "Electromagnetic Compatibility - Limits - Limitations for Voltage Changes, Voltage Fluctuations, and Flicker in Public Low-Voltage Supply Systems for Equipment with Rated Current ≤16A and Subjected to Conditional Connection"

GB 17625.2 "Electromagnetic Compatibility - Limits - Limitations for Voltage Changes, Voltage Fluctuations, and Flicker in Public Low-Voltage Supply Systems for Equipment with Rated Current ≤16A and Subjected to Conditional Connection"

IEC 62493/GB T31275: "Assessment of Human Exposure to Electromagnetic Fields from Lighting Equipment"

IEC 60947-1/GB 10408.1: "Low-Voltage Switchgear and Controlgear - Part 1: General Rules"

IEC 60947-2/GB 10408.2: "Low-Voltage Switchgear and Controlgear - Part 2: Circuit Breakers"

IEC 60947-3/GB 10408.3: "Low-Voltage Switchgear and Controlgear - Part 3: Switches, Disconnectors, Switch-Disconnectors, and Fuse-Combination Units"

IEC 60947-4/GB 10408.4: "Low-Voltage Switchgear and Controlgear - Part 4-1: Contactors and Motor Starters - Electromechanical Contactors and Motor Starters (Including Motor Protectors)"

IEC 60947-5/GB 10408.5: "Low-Voltage Switchgear and Controlgear - Part 5-1: Control Circuit Devices and Switching Elements - Electromechanical Control Circuit Devices"

IEC 60947-6/GB 10408.6: "Low-Voltage Switchgear and Controlgear - Part 4-2: Contactors and Motor Starters - AC Semiconductor Motor Controllers and Starters (Including Soft Starters)"

IEC 60947-10/GB 10408.10: "Low-Voltage Switchgear and Controlgear - Part 5-2: Control Circuit Devices and Switching Elements - Proximity Switches"

CISPR 11/EN 55011/GB 4824: "Limits and Measurement Methods of Industrial, Scientific, and Medical (ISM) Radio-Frequency Equipment Electromagnetic Disturbance Characteristics"

iec 60601-1-2/YY 0505: "Medical Electrical Equipment - Part 1-2: General Requirements for Safety - Collateral Standard: Electromagnetic Compatibility - Requirements and Tests"

iec 61326-1/GB T18268.1: "Electrical Equipment for Measurement, Control, and Laboratory Use - EMC Requirements - Part 1: General Requirements"

IEC 61326-2-6/GB T18268.26: "Electrical Equipment for Measurement, Control, and Laboratory Use - EMC Requirements - Part 26: In Vitro Diagnostic (IVD) Equipment"

IEC 61000-3-2/GB 17625.1: "Electromagnetic Compatibility - Limits - Harmonic Current Emission Limits (Equipment with Input Current ≤16

 

A per Phase)"

IEC 61000-3-3/GB 17625.2: "Electromagnetic Compatibility - Limits - Limitations for Voltage Changes, Voltage Fluctuations, and Flicker in Public Low-Voltage Supply Systems for Equipment with Rated Current ≤16A and Subjected to Conditional Connection"

IEC 61000-3-2/GB 17625.1: "Electromagnetic Compatibility - Limits - Harmonic Current Emission Limits (Equipment with Input Current ≤16A per Phase)"

CISPR 14-1/GB 4343.1: "Electromagnetic Compatibility Requirements for Household Electrical Appliances, Electric Tools, and Similar Apparatus - Part 1: Emission"

CISPR 14-2/GB 4343.2: "Electromagnetic Compatibility Requirements for Household Electrical Appliances, Electric Tools, and Similar Apparatus - Part 2: Immunity"

CISPR 22/EN 55022/GB 9254: "Radio Disturbance Characteristics of Information Technology Equipment - Limits and Methods of Measurement"

CISPR 24/GB/T 17618: "Electromagnetic Compatibility - Immunity Requirements and Measurement Methods for Information Technology Equipment"


Email:hello@jjrlab.com


Leave Your Message


Write your message here and send it to us


Related News
Read More >>
Amazon TIC Direct Validation Compliance Amazon TIC Direct Validation Compliance
09 .30.2025
Amazon now requires some US site products be verified by Amazon-approved TIC labs; sellers can’t upl...
Can Old Amazon TIC Direct Validation Reports Still Can Old Amazon TIC Direct Validation Reports Still
09 .30.2025
Amazon TIC DV needs full CPC reports within 1 year. JJR Lab offers standard toy testing and DV submi...
Children’s Toy Testing CPSC Compliance Laboratory Children’s Toy Testing CPSC Compliance Laboratory
09 .30.2025
JJR Lab provides CPSC-compliant toy testing, covering CPSIA, ASTM F963, EN71, lead, phthalates, and ...
ASTM F963-23 Heavy Metal Testing ASTM F963-23 Heavy Metal Testing
09 .30.2025
JJR Lab provides ASTM F963-23 testing for toys, covering heavy metals, lead, phthalates, flammabilit...
What Is Amazon Italy WEEE Registration? What Is Amazon Italy WEEE Registration?
09 .29.2025
Italian WEEE requires EPR registration & testing per EU standards (RoHS, REACH, EMC). JJR Lab of...
Amazon Toys Category Mandatory Direct Validation Amazon Toys Category Mandatory Direct Validation
09 .29.2025
Amazon now requires Direct Validation for toys: ASTM F963, CPSIA, EN71, EN62115 tests. JJR Laborator...
What Is the SDS File Required by Amazon? What Is the SDS File Required by Amazon?
09 .29.2025
Amazon requires a Safety Data Sheet (SDS) for chemical or hazardous products. JJR Lab offers SDS pre...
What Is UK WEEE Compliance? What Is UK WEEE Compliance?
09 .29.2025
UK WEEE compliance (Aug 2025) requires overseas sellers to report sales, pay recycling fees; include...

Leave Your Message