EMC China Lab

How to get a UL 60335 Test Report

Views :
Update time : 2026-10-26

Introduction to the UL 60335 Standard

UL 60335 is the mandatory safety testing standard system for household and similar electrical appliances in the U.S. and North American markets. It consists of two parts: UL 60335-1 (General Safety Requirements) and a series of UL 60335-2-xx (Particular Requirements for specific products). This standard covers core items such as electrical safety, mechanical structure, temperature rise limits, fire resistance and flame retardancy, and abnormal fault protection. It is the most common compliance admission basis for platforms like Amazon and Temu regarding small household appliances, heating appliances, and motor-operated appliances.


Applicable Products and Standards for UL 60335

UL 60335-1: General safety requirements for household and similar electrical appliances (Mandatory)

UL 60335-2-xx: Particular requirements for specific products (Must be issued together for platform review)


Common Correspondences:

1.Hair clippers / Shavers UL 60335-2-8

2.Refrigerators / Ice makers / Dehumidifiers UL 60335-2-24 / 2-40

3.Chargers / Battery adapters UL 60335-2-29

4.Hair dryers / Curling irons ul 859 (Still used in some scenarios; platforms are gradually transitioning to the 60335 system)

5.Air fryers / Ovens Corresponding heating-related Part 2 standards

6.Products with lithium batteries Usually supplemented by ul 1642 (Cell) + ul 2054 (Battery pack)

Warning: If you only get UL 60335-1 without Part 2, Amazon is highly likely to reject your review directly.


UL 60335 Testing Process

Standard Confirmation and Pre-evaluation

Provide:

1.Product name, model, voltage (e.g., 120V 60Hz), power

2.Function description (whether it heats, has a motor, is waterproof, or is wireless)

3.Internal structure schematic diagram


Laboratory Engineer Matching:

UL 60335-1 + Correct Part 2 + Additional standards (Battery / Wireless / fcc)

Outputs: Test item list, lead time, and quotation.


Prepare Technical Documentation

Usually Required:

1.Product specification sheet (in English)

2.Electrical schematic diagram, PCB layout diagram

3.BOM critical components list (motor, switch, thermostat, fuse, power cord, plastic enclosure)

4.Critical components certificates: Priority should be given to materials with UL Yellow Card / UL File Number

5.Nameplate label draft (including voltage, model, and warning text)

6.English user manual (including safety warnings)

7.Appearance photos, structural exploded view

8.Built-in battery: UL 1642 / UL 2054 reports

9.Platform information: ASIN (for Amazon review)


Send Samples

Conventional Sample Quantity:

1.Simple small appliances: 2–3 units

2.Motor-driven / High-power / Complex structures: 3–5 units

3.Destructive testing (locked-rotor, drop, needle-flame) will consume samples

Requirement: Must send mass-production versions; do not use prototype samples to cope with testing.


JJR Laboratory Testing

Core Testing Modules:

Electrical Safety

1.Hi-pot (Dielectric withstand) test

2.Insulation resistance

3.Leakage current

4.Ground continuity

5.Clearance and creepage distances


Thermal and Abnormal Tests (High-frequency failure points)

1.Full-load temperature rise

2.Motor locked-rotor

3.Thermostat failure simulation

4.Single-fault condition: No fire, no melting


Mechanical and Structural

1.Protection against electric shock

2.Enclosure strength

3.Isolation of moving parts


Fire Resistance and Flame Retardancy

1.Plastic enclosure ul 94 rating (Common requirement: V-0 / V-1)

2.Ball pressure test, needle-flame test


Markings and Manuals

1.Complete nameplate parameters

2.Compliant English safety warnings


Issue Official Report + Platform Submission

The official report should include:

1.Laboratory ISO/IEC 17025 qualification page

2.Standard number and version

3.Sample photos, nameplate photos

4.Test data records

5.Critical components list

6.Conclusion: Pass


Amazon Back-end Path:

1.Compliance Request Upload Test Report PDF + Qualification Proof + Product Images

2.Ensure: Brand, model, and ASIN match the report character for character.


Lead Time, Cost, and How to Choose an Agency

Lead Time Reference

1.Simple products without rectification: 5–7 working days

2.Conventional household appliances: 7–15 working days

3.Complex / Multi-model / Requiring rectification: 3–4 weeks

4.Expedited service: 3–5 working days (Usually incurs an additional fee)


Cost Influencing Factors

1.Product power and complexity

2.Presence of a motor, heating, or battery

3.Market Range Reference: Third-party ul test reports generally range between $1,350 and $4,500; complete UL certification requires separate annual fees.


FAQ

Where can I go to get a UL 60335 test report myself?

You cannot "do it yourself." It must be sent to a third-party testing laboratory with ISO 17025 qualifications, and the laboratory will issue the report.


Do I still need UL 60335 if I have a CE report?

Yes. CE is the European Union system, while UL is the North American safety standard system. Their testing logic differs, and the Amazon U.S. marketplace does not accept CE as a substitute for UL.


How long is the validity period of a UL test report?

The report itself is valid long-term, but platforms usually require it to be issued within 1 year. If the product structure changes or critical materials are replaced, retesting or supplementary evaluation is required.


Can I print the UL logo after geting the report?

No. Before completing the full ul certification process, it is strictly prohibited to print the UL logo on the product or packaging, otherwise it constitutes infringement.


Is doing only UL 60335 enough for household appliances with built-in lithium batteries?

Not enough. It is usually necessary to match:

UL 1642 (Cell)

UL 2054 (Battery pack)

Wireless functions additionally require FCC consideration



Email:hello@jjrlab.com


Leave Your Message


Write your message here and send it to us


Related News
Read More >>
What is 16 CFR 1260 Compliance for Window Covering What is 16 CFR 1260 Compliance for Window Covering
11 .11.2026
Get 16 CFR 1260 compliance testing for custom window coverings at JJR Laboratory. ISO/IEC 17025 accr...
Differences Between F2923 and F2999 Differences Between F2923 and F2999
11 .11.2026
Need ASTM F2923 & F2999 testing for US Amazon jewelry compliance? JJR LAB is a CMA & CNAS ac...
How to get the FMVSS No.108 Test Report for Car Li How to get the FMVSS No.108 Test Report for Car Li
11 .11.2026
Obtain your FMVSS 108 test report for car lights with JJR Lab. As an ISO/IEC 17025, CMA, and CNAS ac...
What is Motorcycle Helmet FMVSS No. 218 Compliance What is Motorcycle Helmet FMVSS No. 218 Compliance
11 .11.2026
Ensure Amazon US/Canada motorcycle helmet FMVSS 218 compliance with JJR Laboratory. We offer trusted...
Amazon Baby Crib TIC Verification Amazon Baby Crib TIC Verification
11 .11.2026
Get Amazon Baby Crib TIC verification with JJR LAB. We provide ISO/IEC 17025, CMA, and CNAS accredit...
Amazon TIC Verification for Cribs with Changing Ta Amazon TIC Verification for Cribs with Changing Ta
11 .11.2026
Amazon TIC verification for cribs with changing tables! JJR LAB offers ISO/IEC 17025 accredited, CMA...
How to get an Amazon 16 CFR 1243 Test Report? How to get an Amazon 16 CFR 1243 Test Report?
11 .10.2026
Need an Amazon 16 CFR 1243 test report for infant support cushions? Contact JJR LAB, a CMA & CNA...
Infant Support Cushions 16 CFR 1243 2026 Infant Support Cushions 16 CFR 1243 2026
11 .10.2026
Ensure 16 CFR 1243 compliance for infant support cushions. JJR Lab offers CMA & CNAS accredited ...

Leave Your Message