EMC China Lab

5G WiFi Regulatory Testing and Certification Laboratory

Views :
Update time : 2024-08-16

With the advancement of technology, the fifth-generation WiFi communication technology (using the 802.11ac protocol) has emerged and rapidly developed. The 802.11ac protocol operates in the 5GHz frequency band, parts of which overlap with radar bands in various countries. For the 5GHz frequency band, there are two additional testing requirements according to national regulations—DFS (Dynamic Frequency Selection) and TPC (Transmit Power Control) (optional).

 

When the bandwidth of 5G WiFi increases to 80MHz or higher, the transmission speed can reach up to 1Gbps or more, enabling the transfer of approximately 125MB of content per second; continuous updates and improvements are ongoing. Such a high-frequency, high-speed communication protocol imposes higher and stricter demands on testing instruments and equipment, and also raises the technical skill requirements for operators. Therefore, the European Union has updated its Adaptivity requirements to better improve spectrum efficiency.

 

China’s JJR EMC Laboratory is equipped with a full set of 5G WiFi automated testing systems, with dozens of professional and experienced experts on standby to help you better comply with the new requirements. Customized testing services, along with the SGS automated testing system and professional experts, will make your product stand out.

 

What product certification tests are provided?

5G WiFi wireless products, such as routers, mobile phones, and televisions.

 

5G Testing Standards

1. European CE: ETSI EN 301 893

2. United States fcc: 47CFR

3. japan mic: MIC Article 2 No.88

 

5G Testing Items/Regulatory Requirements

Regulatory compliance testing (including DFS + Adaptivity), customized testing, and pre-production predictive testing.

 

5G-Related FAQs

 

How are the 5G frequency bands allocated in various countries?

1. European CE

   (1) 5150MHz-5350MHz

   (2) 5470MHz-5725MHz

2. United States FCC

   (1) 5150MHz-5350MHz

   (2) 5450MHz-5725MHz

   (3) 5725MHz-5850MHz

3. Japan MIC

   (1) 5150MHz-5350MHz

   (2) 5470MHz-5725MHz

 

What is DFS testing, and why is it necessary?

Concept: DFS (Dynamic Frequency Selection) refers to dynamic frequency selection.

Reason: The 5250MHz-5350MHz and 5470MHz-5725MHz bands are globally used by radar systems. To avoid interfering with radar operations while still being able to use this spectrum, countries have added DFS testing requirements on top of traditional 5G WiFi testing.

 

Do all 5G frequency bands require DFS testing?

DFS testing is required if your product operates in the following frequency bands:

1. European CE

   (1) 5250MHz-5350MHz

   (2) 5470MHz-5725MHz

2. United States FCC

   (1) 5250MHz-5350MHz

   (2) 5470MHz-5725MHz

3. Japan MIC

   (1) 5250MHz-5350MHz

   (2) 5470MHz-5725MHz

 

Do all 5G frequency bands require Adaptivity testing?

For CE certification, Adaptivity testing is required whenever complying with ETSI EN 301 893 standards.

 

If a product has multiple antennas, does each antenna need to be tested?

This depends on the specific testing item. Please provide engineering samples with individual transmission, MIMO transmission, and normally operating samples for testing.


Email:hello@jjrlab.com


Leave Your Message


Write your message here and send it to us


Related News
Read More >>
Humidifier CSA C22.2 No.104 Standard Testing Humidifier CSA C22.2 No.104 Standard Testing
07 .30.2026
Ensure North American compliance for humidifiers. JJR Laboratory provides CSA C22.2 No.104 standard ...
Portable Luminaire SCC Recognized CSA Test Report Portable Luminaire SCC Recognized CSA Test Report
07 .30.2026
Need a Portable Luminaire CSA Test Report for Canadian market access? JJR Laboratory provides expert...
Compliance Guide for Lithium Battery Home Applianc Compliance Guide for Lithium Battery Home Applianc
07 .30.2026
Avoid Amazon Canada listing removals! JJR Laboratory provides official CSA C22.2 & UN 38.3 testi...
What is the CSA C22.1 Test Report for Electric Ket What is the CSA C22.1 Test Report for Electric Ket
07 .30.2026
Need Amazon Canada electric kettle compliance? JJR Laboratory provides fast testing for CSA C22.1 an...
Electric Kettle Canada SOR/2016-181 Testing: CSA 2 Electric Kettle Canada SOR/2016-181 Testing: CSA 2
07 .30.2026
Ensure your electric kettles meet Amazon Canada SOR/2016-181, CSA 22.2 No.60335-2-15, or C22.2 No.64...
How to Achieve Compliance with the EU EN55032 Stan How to Achieve Compliance with the EU EN55032 Stan
07 .29.2026
Ensure seamless EU market access for your multimedia equipment. JJR Laboratory provides professional...
EU EN301908 Standard for Mobile Communication Prod EU EN301908 Standard for Mobile Communication Prod
07 .29.2026
Secure EU market access for your mobile communication products. JJR Lab provides professional EN3019...
What is the Vacuum Cleaner CSA C22.2 No.243 Test R What is the Vacuum Cleaner CSA C22.2 No.243 Test R
07 .29.2026
JJR Laboratory provides CSA C22.2 No.243 testing for vacuum cleaners. Get your safety report to clea...

Leave Your Message