Safety of Household and Similar Electrical Appliances: Special Requirements for Battery Chargers
en60335-2-29 Test Report, iec 60335-2-29, AS/NZS 60335.2.29 Test Report.
1. Marking and Instructions
- EN60335-2-29:2004 + A2:2010 + A11:2018 (Clause 7)
- IEC 60335-2-29:2016 + AMD1:2019 (Clause 7)
- AS/NZS 60335.2.29:2017 (Clause 7)
2. Protection Against Electric Shock
- EN60335-2-29:2004 + A2:2010 + A11:2018 (Clause 8)
- IEC 60335-2-29:2016 + AMD1:2019 (Clause 8)
- AS/NZS 60335.2.29:2017 (Clause 8)
3. Input Power and Current
- EN60335-2-29:2004 + A2:2010 + A11:2018 (Clause 10)
- IEC 60335-2-29:2016 + AMD1:2019 (Clause 10)
- AS/NZS 60335.2.29:2017 (Clause 10)
4. Heating
- EN60335-2-29:2004 + A2:2010 + A11:2018 (Clause 11)
- IEC 60335-2-29:2016 + AMD1:2019 (Clause 11)
- AS/NZS 60335.2.29:2017 (Clause 11)
5. Leakage Current and Electrical Strength at Operating Temperature
- EN60335-2-29:2004 + A2:2010 + A11:2018 (Clauses 13.2, 13.3)
- IEC 60335-2-29:2016 + AMD1:2019 (Clauses 13.2, 13.3)
- AS/NZS 60335.2.29:2017 (Clauses 13.2, 13.3)
6. Moisture Resistance
- EN60335-2-29:2004 + A2:2010 + A11:2018 (Clause 15.3)
- IEC 60335-2-29:2016 + AMD1:2019 (Clause 15.3)
- AS/NZS 60335.2.29:2017 (Clause 15.3)
7. Leakage Current and Electrical Strength
- EN60335-2-29:2004 + A2:2010 + A11:2018 (Clauses 16.2, 16.3)
- IEC 60335-2-29:2016 + AMD1:2019 (Clauses 16.2, 16.3)
- AS/NZS 60335.2.29:2017 (Clauses 16.2, 16.3)
8. Overload Protection of Transformers and Associated Circuits
- EN60335-2-29:2004 + A2:2010 + A11:2018 (Clause 17)
- IEC 60335-2-29:2016 + AMD1:2019 (Clause 17)
- AS/NZS 60335.2.29:2017 (Clause 17)
9. Durability
- EN60335-2-29:2004 + A2:2010 + A11:2018 (Clause 18)
- IEC 60335-2-29:2016 + AMD1:2019 (Clause 18)
- AS/NZS 60335.2.29:2017 (Clause 18)
10. Abnormal Operation
- EN60335-2-29:2004 + A2:2010 + A11:2018 (Clause 19)
- IEC 60335-2-29:2016 + AMD1:2019 (Clause 19)
- AS/NZS 60335.2.29:2017 (Clause 19)
11. Stability and Mechanical Hazards
- EN60335-2-29:2004 + A2:2010 + A11:2018 (Clause 20.1)
- IEC 60335-2-29:2016 + AMD1:2019 (Clause 20.1)
- AS/NZS 60335.2.29:2017 (Clause 20.1)
12. Mechanical Strength
- EN60335-2-29:2004 + A2:2010 + A11:2018 (Clause 21)
- IEC 60335-2-29:2016 + AMD1:2019 (Clause 21)
- AS/NZS 60335.2.29:2017 (Clause 21)
13. Construction
- EN60335-2-29:2004 + A2:2010 + A11:2018 (Clause 22)
- IEC 60335-2-29:2016 + AMD1:2019 (Clause 22)
- AS/NZS 60335.2.29:2017 (Clause 22)
14. Internal Wiring
- EN60335-2-29:2004 + A2:2010 + A11:2018 (Clause 23)
- IEC 60335-2-29:2016 + AMD1:2019 (Clause 23)
- AS/NZS 60335.2.29:2017 (Clause 23)
15. Power Connections and External Flexible Cords
- EN60335-2-29:2004 + A2:2010 + A11:2018 (Clause 25)
- IEC 60335-2-29:2016 + AMD1:2019 (Clause 25)
- AS/NZS 60335.2.29:2017 (Clause 25)
16. External Wiring Terminals
- EN60335-2-29:2004 + A2:2010 + A11:2018 (Clause 26)
- IEC 60335-2-29:2016 + AMD1:2019 (Clause 26)
- AS/NZS 60335.2.29:2017 (Clause 26)
17. Grounding Protection
- EN60335-2-29:2004 + A2:2010 + A11:2018 (Clause 27)
- IEC 60335-2-29:2016 + AMD1:2019 (Clause 27)
- AS/NZS 60335.2.29:2017 (Clause 27)
18. Screws and Connections
- EN60335-2-29:2004 + A2:2010 + A11:2018 (Clause 28)
- IEC 60335-2-29:2016 + AMD1:2019 (Clause 28)
- AS/NZS 60335.2.29:2017 (Clause 28)
19. Creepage Distances and Clearances
- EN60335-2-29:2004 + A2:2010 + A11:2018 (Clause 29)
- IEC 60335-2-29:2016 + AMD1:2019 (Clause 29)
- AS/NZS 60335.2.29:2017 (Clause 29)
20. Resistance to Heat and Fire
- EN60335-2-29:2004 + A2:2010 + A11:2018 (Clause 30)
- IEC 60335-2-29:2016 + AMD1:2019 (Clause 30)
- AS/NZS 60335.2.29:2017 (Clause 30)
21. Battery-Operated Appliances
- EN60335-2-29:2004 + A2:2010 + A11:2018 (Annex B)
- IEC 60335-2-29:2016 + AMD1:2019 (Annex B)
How to get a D-U-N-S® Number for US FDA Registrati
Household Massage Devices Compliance in the China
Compliance for the Global In Vitro Diagnostic (IVD
Compliance Guide for Nebulizers in European and Am
Cybersecurity Certification Service for EU RED Dir
ANATEL Certification Compliance Guide for Brazil M
Energy Storage Battery Brazil Inmetro Certificatio
Southeast Asia Compliance Requirements for EV Char
24-hour online customer service at any time to respond, so that you worry!