We understand that you are looking for an EMC (Electro Magnetic Compatibility) testing laboratory in Chicago. However, we still want to help you understand us; because compared to local Australian laboratories, we can save you 30% on testing and certification costs.
JJRLAB is a Chinese EMC electromagnetic compatibility testing laboratory; we are an ISO/IEC 17025 and GLP laboratory. Welcome to learn more about us.
Electromagnetic compatibility (EMC) refers to the ability of a device or system to operate in accordance with requirements in its electromagnetic environment and not to generate intolerable electromagnetic interference to any device in its environment. Therefore, EMC includes two requirements: on the one hand, ( EMI ) means that the electromagnetic interference generated by the device to the environment during normal operation cannot exceed a certain limit; on the other hand, ( EMS ) means that the device has a certain degree of immunity to the electromagnetic interference in the environment, that is, electromagnetic sensitivity.
1 1 10-meter anechoic chamber,
1 3-meter EMC anechoic chamber (9m*6m*6m)
1 3-meter full anechoic chamber (7m*4m*3m)
1 conductive standard shielding room
1 Electromagnetic Sensitivity (EMS) standard shielding room
4 9mX6mX6m standard full (semi) anechoic chambers, efficient EMC rectification team, welcome to consult!
EMI testing includes | ||
Test items | standard test | Test Specifications |
Radiated Emission | CISPR/EN 55011 、 EN 55013、EN 55015、CISPR 15、EN 55014、EN 55032、CISPR 22、EN 55035、EN61547、EN60598 、Part 15B 、Part 18、EN 301 489 、YY0505、GB/T18268.1、GB/ T 18268.26 | 9K~26.5GHz |
Conducted interference | CISPR/EN 55011 、 EN 55013、EN 55015、CISPR 15、EN 55014、EN 55032、CISPR 22、EN 55035、EN61547、EN60598 、Part 15B 、Part 18、EN 301 489 、YY0505、GB/T18268.1、GB/ T 18268.26 | 9kHz~30MHz |
Disturbance power | EN 55014、CISPR 14-1、EN 55013、EN 55032、CISPR 13 | 30~300MHz |
Magnetic field radiation | CISPR/EN 55032,14-1 | 9k~30MHz |
Harmonic current | IEC/EN 61000-3-2、GB 17625.1 | 1st to 40th harmonic |
Voltage fluctuations and flicker | IEC/EN 61000-3-3 、GB 17625.2 | AC 200 to 250 V |
EMS testing includes | ||
Test items | standard test | Test Specifications |
Electrostatic immunity | IEC/EN61000-4-2、GB/T 17626.2 | 2-30kV |
Radiated immunity | IEC/EN61000-4-3、GB/T 17626.3 | 26MHz~3GHz |
Electrical fast transient burst immunity | IEC/EN61000-4-4、GB/T 17626.4 | 0-4kV |
Surge immunity | IEC/EN61000-4-5、GB/T 17626.5 | 0-4kV |
Conducted Immunity | IEC/EN61000-4-6、GB/T 17626.6 | 10V (150~230MHz) |
Power frequency magnetic field immunity | IEC/EN61000-4-8、GB/T 17626.8 | 1~30A |
Voltage sag, short interruption immunity | IEC/EN61000-4-11、GB/T 17626.11 | Voltage change: |
YY 0505-2012
GB/T 18268.1-2010
GB/T 18268.26-2010