EMC China Lab

SIRIM Certification for Battery Exports to Malaysia

Views :
Update time : 2025-12-30

Recently, Standards and Industrial Research Institute of Malaysia (SIRIM) officially released the Guidelines for Certification and Labeling of Various Batteries and Energy Storage Devices, providing a clear technical pathway for relevant products to enter the Malaysian market.

 

Currently, this certification system remains voluntary and is not a mandatory requirement.

 

SIRIM Certification for Battery Exports to Malaysia(图1)


Certification Types

SIRIM Malaysia offers two main certification pathways for batteries, allowing enterprises to make flexible choices based on their export strategies.

 

Core Differences and Selection Recommendations

◉ Type 1B (Batch Certification)

Applicable to enterprises with low-frequency export needs. The certification process is relatively simple. However, samples of each batch of goods must be sent to Malaysia for testing and affixed with specific labels.

◉ Type 5 (Product Certification)

Suitable for clients planning long-term, multi-batch exports. A factory audit is required in the first year, which entails a relatively high initial investment. Nevertheless, within the one-year validity period of the certificate, subsequent batches do not need to be resubmitted for testing—greatly improving customs clearance efficiency and flexibility, and proving to be more cost-effective and convenient in the long run.

Certification Requirements

Type 5

Type 1B (Batch)

Applicant Type

Local or overseas company<br>(Overseas applicants must appoint a local agent)

Local or overseas company<br>(Overseas applicants must appoint a local agent)

Certificate Validity

1 year

One-time validity<br>(Limited to the specific batch)

Certificate Renewal

Annual renewal<br>(Subject to supervision audit)

Reapplication required for each batch<br>with a batch verification report issued

Factory Audit

Required

Not required

Sample Testing

Conducted on an as-needed basis

Required for each batch

Market Supervision

Applicable

Applicable

 

Product Scope and Applicable Standards

When applying for sirim certification in Malaysia, different types of battery products must comply with the corresponding international standards below:

Lithium Batteries

◉ UPS Backup Batteries/Energy Storage Systems

IEC 62040-1

◉ Light Electric Vehicle Batteries

UN R136 and/or IEC 62619, IEC 62660-3, and un 38.3

◉ Electric Vehicle Batteries

UN R100, IEC 62660-3, and UN 38.3

◉ Portable Device Batteries

MS iec 62133, or IEC 62133-2, and UN 38.3

◉ Industrial and Energy Storage Batteries

IEC 62619, and/or IEC 63056

Lead-Acid Batteries

◉ Stationary Vented Energy Storage Batteries

IEC 60896-11

◉ Stationary Valve-Regulated Energy Storage Batteries

IEC 60896-21 and IEC 60896-22

◉ Starter Batteries

• Starter batteries for passenger vehicles and commercial/industrial vehicles:

MS 45, IEC 60095-1, or JIS D 5301

• Starter batteries for motorcycles:

IEC 60095-7, or JIS D 5302

Nickel-Based Batteries

◉ Portable Device Batteries

MS IEC 62133, or IEC 62133-1

 

Certification Process

1. Prepare Technical Documents

This is the foundation of certification, including detailed product information, importer data, power of attorney, application form, as well as the crucial complete cb test report and un 38.3 test report.

2. Select Certification Type

Determine whether to apply for Type 1B Batch Certificate or Type 5 PCS Certificate based on your export plan.

3. Execute the Certification Process

◉ If Type 1B is selected, arrange for sample delivery to Malaysia for testing for each batch and obtain the certificate for that specific batch.

◉ If Type 5 is selected, undergo the factory audit arranged by SIRIM; upon passing the audit, a certificate with a one-year validity period will be issued.


Email:hello@jjrlab.com


Leave Your Message


Write your message here and send it to us


Related News
Read More >>
What is Cytotoxicity ISO 10993-5 What is Cytotoxicity ISO 10993-5
09 .29.2026
ISO 10993-5 cytotoxicity testing at JJR LAB uses cell culture hardware and analyzers to measure cell...
What is Hemocompatibility Testing ISO 10993? What is Hemocompatibility Testing ISO 10993?
09 .29.2026
ISO 10993-4 hemocompatibility testing uses blood-contact test systems, flow probes and analyzers to ...
What is ISO 10993-5 Tests for In Vitro Cytotoxicit What is ISO 10993-5 Tests for In Vitro Cytotoxicit
09 .29.2026
ISO 10993-5 cytotoxicity testing at JJR LAB uses L929 cells, MTT hardware and extraction methods to ...
Electronic Product IEC 62368-1 Safety Testing Electronic Product IEC 62368-1 Safety Testing
09 .28.2026
JJR Lab provides IEC 62368-1 safety testing for AV and ICT products, covering HBSE, electric shock, ...
What is an EU SDS (Safety Data Sheet)? What is an EU SDS (Safety Data Sheet)?
09 .25.2026
JJR Lab explains EU SDS requirements under REACH, CLP and EU 2020/878, including 16-section Safety D...
What is the CA Prop 65 Warning Label? What is the CA Prop 65 Warning Label?
09 .24.2026
JJR Lab explains CA Prop 65 warning labels and compliance testing for lead, cadmium, phthalates and ...
2026 Amazon TIC Mandatory Audit Catalog 2026 Amazon TIC Mandatory Audit Catalog
09 .24.2026
2026 Amazon TIC Mandatory Audit Catalog by JJR Lab covers UN38.3, UL 4200A, ASTM F963, FCC Part 15C,...
Australian Electrical EESS and RCM Compliance Australian Electrical EESS and RCM Compliance
09 .24.2026
Australian EESS and RCM compliance with AS/NZS 4417, AS/NZS 3199 and IEC 60974-1 testing. JJR Testin...

Leave Your Message