EMC China Lab

UL507 Test Report for Electric Fans

Views :
Update time : 2025-02-18

The United States has stringent safety requirements, and domestic electronic product manufacturers have been required to undergo relevant safety compliance testing for many years. With Amazon's growing strategic importance in global commerce, an increasing number of foreign electronic devices are entering the U.S. market via Amazon. However, the U.S. does not impose mandatory safety compliance testing on foreign manufacturers.

 

Due to a series of fire incidents caused by electronic products, on September 24, 2017, U.S. authorities issued regulations specifically targeting e-commerce. These regulations require Amazon to notify overseas sellers on its platform to provide relevant safety compliance reports. Before submitting a UL standard test report, Amazon must order sellers to halt sales. Additionally, the U.S. mandates that test reports must be issued by laboratories accredited under ISO/IEC 17025 or ILAC ISO 17025 standards.

 

Scope of UL507 Standard for Electric Fans

UL507 applies to the following types of products:

a) Air circulation fans and blowers, such as desktop, ceiling, and hanging fans.

b) Ventilation fans and blowers, including attic, wall-mounted, ceiling-insert, household range hoods, canopy-type, and window fans.

c) Dryer-type fans used for drying carpets or floors.

d) Evaporative coolers.

e) Air filtration equipment.

f) Fan-type deodorizers and air fresheners.

g) Component fans.

h) Low-voltage component fans.

 

ul 507 Test Items

1. Leakage current test; grounding continuity test

2. Inrush current test; input test; temperature rise test

3. Dielectric strength test; waterproof test; locked rotor test

4. Damp condition test; power cord torque test

5. Unprotected blade test; power cord thrust test

6. Oscillation test; enclosure impact test

7. Enclosure static pressure test; portable fan blade test

8. Drop test; handle safety test; stability test

 

Amazon's Requirements for Testing Laboratories

Amazon's U.S. site requires laboratories accredited under ILAC ISO/IEC 17025 standards.

 

Cost of ul test report

The cost depends on the product’s features, as different products require different tests. In China, JJR Laboratory charges between $550 and $800 for ul testing.

 

Processing Time for UL Test Report

The standard processing time is 5-7 business days. If the product fails the test, a new sample must be provided for re-testing.

 

Validity of the UL Test Report

As long as the UL testing standard remains unchanged, the UL test report remains valid indefinitely.

 

Our Advantages

- 25 years of experience in international regulatory certification.

- 20 years of expertise in cross-border e-commerce compliance.

- ISO 17025 accredited, meeting platform qualification requirements.

- Comprehensive services from product testing to complianCE certification.

For further inquiries, feel free to contact us!


Email:hello@jjrlab.com


Leave Your Message


Write your message here and send it to us


Related News
Read More >>
Mandatory Standard for Portable Power Banks GB 473 Mandatory Standard for Portable Power Banks GB 473
04 .12.2026
New mandatory GB 47372-2026 standard strengthens portable power bank safety through stricter cell te...
ISO 10993-10 In Vitro Skin Sensitization Test Serv ISO 10993-10 In Vitro Skin Sensitization Test Serv
04 .11.2026
In vitro skin sensitization tests assess allergic risks for safety use. JJR LAB offers ISO 10993-10 ...
What is ISO 10993 Biocompatibility Testing? What is ISO 10993 Biocompatibility Testing?
04 .11.2026
JJR is a CNAS- and ISO/IEC 17025-accredited Laboratory providing ISO 10993 compliance testing. Repor...
How to Perform a Valid CCK-8 Cytotoxicity Assay How to Perform a Valid CCK-8 Cytotoxicity Assay
04 .10.2026
A valid CCK-8 cytotoxicity assay uses WST-8 to assess cell viability via color change, with key step...
Introduction to Cytotoxicity Assay (CCK-8 Method) Introduction to Cytotoxicity Assay (CCK-8 Method)
04 .10.2026
CCK-8 assay measures viable cells via WST-8 conversion, enabling rapid, sensitive detection for drug...
What Are the Cytotoxicity Assay Methods? What Are the Cytotoxicity Assay Methods?
04 .10.2026
Cytotoxicity assays reveal cell safety by measuring viability or damage. JJR LAB outlines methods li...
What is Ingress Protection (IP) Testing and Standa What is Ingress Protection (IP) Testing and Standa
04 .08.2026
Ingress Protection (IP) defines enclosure resistance to dust and water per IEC 60529; JJR LAB verifi...
What is UL 153 Lighting Standards and Portable Lum What is UL 153 Lighting Standards and Portable Lum
04 .08.2026
UL 153 defines safety rules for portable luminaires; Amazon requires compliant testing. JJR verifies...

Leave Your Message