EMC China Lab

NMPA Certification and GB 9706 Testing for Dental Equipment

Views :
Update time : 2024-08-29

What is Dental Medical Equipment? 

Dental equipment refers to a range of specialized tools and instruments used in dental treatment, examination, diagnosis, and surgery. These devices assist dentists in performing various treatments on teeth, gums, and the oral cavity.

 NMPA Certification and GB 9706 Testing for Dental Equipment(图1)

What are the types of Dental Medical Equipment? 

Dental chair, dental handpiece, X-ray machine, dental probe, ultrasonic scaler, dental curing light, saliva ejector, sterilization equipment, dental microscope, root canal treatment equipment, implant systems, dental imaging equipment.

 

Testing Standards for Dental Equipment in China 

GB 9706.260-2020 Medical Electrical Equipment—Part 2-60: Particular requirements for the basic safety and essential performance of dental equipment 

GB 9706.260 applies to the basic safety and essential performance requirements for dental units, dental patient chairs, dental hand-held devices, and oral lights (hereinafter collectively referred to as dental equipment). 

GB 9706.260 does not include amalgamators, sterilization equipment, and dental X-ray equipment. 

Apart from the content specified in sections 7.2.13 and 8.4.1 of the general standard, the inherent hazards of the characteristics and functions of medical electrical equipment or systems covered by GB 9706.260 are not explained in the specific requirements of this section. 

The purpose of GB 9706.260 is to establish requirements for the basic safety and essential performance of dental equipment.

 

GB 9706.263-2020 Medical Electrical Equipment—Part 2-63: Particular requirements for the basic safety and essential performance of dental extra-oral X-ray equipment 

GB 9706.263 applies to the basic safety and essential performance (hereinafter referred to as ME equipment) of dental extra-oral X-ray equipment. The scope includes ME systems containing such ME equipment. 

GB 9706.263 includes panoramic equipment, cephalometric equipment, and dental volumetric reconstruction equipment as defined in section 201.3.203. 

The scope of GB 9706.263 is limited to X-ray equipment where the X-ray tube assembly includes high-voltage boundary components, and the geometric relationship between the X-ray source, the area of the patient being imaged, and the X-ray image receptor is pre-set and cannot be arbitrarily changed by the operator during use. 

GB 9706.263 does not include intra-oral dental X-ray equipment. 

The purpose of GB 9706.263 is to establish basic safety and essential performance requirements for ME equipment used in dental extra-oral X-ray imaging.

 

GB 9706.265-2021 Medical Electrical Equipment—Part 2-65: Particular requirements for the basic safety and essential performance of dental intra-oral X-ray equipment 

GB 9706.265 applies to the basic safety and essential performance of intra-oral dental X-ray equipment and its main components, hereinafter referred to as ME equipment. 

The scope of GB 9706.265 is limited to X-ray machines where the X-ray tube assembly contains high-voltage boundary components. 

GB 9706.265 does not apply to extra-oral dental X-ray equipment. 

The scope of GB 9706.265 does not include radiotherapy simulators, bone or tissue absorption densitometers, or dental fluoroscopic equipment. 

The purpose of GB 9706.265 is to establish basic safety and essential performance requirements for ME equipment used in dental intra-oral X-ray imaging.

 

China JJR Laboratory provides GB 9706 testing services for dental medical devices, assisting enterprises in obtaining China's NMPA (CFDA certification) services.


Email:hello@jjrlab.com


Leave Your Message


Write your message here and send it to us


Related News
Read More >>
EU WEEE Directive 2012/19/EU EU WEEE Directive 2012/19/EU
04 .04.2026
EU WEEE Directive 2012/19/EU mandates e-waste recycling and full producer responsibility; JJR LAB of...
What is GB 4806 Certification Compliance What is GB 4806 Certification Compliance
04 .04.2026
GB 4806 sets safety rules for food contact materials, requiring migration and toxicity tests to prev...
What is Japan S-JET Certification? What is Japan S-JET Certification?
04 .04.2026
S-JET is a voluntary Japanese safety certification for high-risk electrical products, boosting trust...
Introduction to RE, CE and ESD in EMC Testing Introduction to RE, CE and ESD in EMC Testing
04 .03.2026
JJR Lab : RE, CE and ESD ensure EMC compliance by controlling emissions and verifying immunity, so d...
EMC Testing: EMI / EMS / RE / CE / CS / ESD EMC Testing: EMI / EMS / RE / CE / CS / ESD
04 .03.2026
EMC ensures devices neither cause nor suffer interference. EMI (CE, RE) measures emissions, while EM...
Important: Latest Notice on SASO IEC 62680 Important: Latest Notice on SASO IEC 62680
04 .03.2026
SASO delays IEC 62680 enforcement to May 1, 2026; non-compliant devices lose COC eligibility. JJR LA...
What is BS EN 1388-2 Certification Testing What is BS EN 1388-2 Certification Testing
04 .03.2026
EN 1388-2 strictly limits lead/cadmium in ceramic tableware; JJR LAB tests heavy metal migration usi...
How to get a BS EN 1388-1 Compliance Report? How to get a BS EN 1388-1 Compliance Report?
04 .03.2026
Ceramic tableware must meet BS EN 1388-1 limits for lead/cadmium; tested via EN 1388-2 under simulat...

Leave Your Message