Radiated Emission (RE) mainly refers to the phenomenon where energy is emitted from a source into space in the form of electromagnetic waves and propagates through space, causing interference to equipment in the surrounding environment.


The 966 Fully Anechoic Chamber Electromagnetic Compatibility (EMC) Laboratory features a 3-meter anechoic chamber, uniquely capable of converting between fully and semi-anechoic configurations. The testing system inside the chamber is provided by the renowned German company R&S (Rohde & Schwarz) and comes equipped with a comprehensive suite of emc testing software. Specifically for mobile phone clients, we offer specialized testing instruments and corresponding supporting software for mobile phone spurious emissions. Additionally, the complete set of EMS (Electromagnetic Susceptibility) equipment in the laboratory is supplied by HTEC, ensuring stable performance and accurate data.


Our current testing capabilities and the test standards we meet include:

EMI Laboratory:

  1. radiated emission test (RE) — Test Standard: en55032

  2. Conducted Emission Test (CE) — Test Standard: EN55032

  3. Harmonic Current Test (Harmonic) — Test Standard: iec 61000-3-2

  4. Voltage Fluctuation and Flicker Test (Flicker) — Test Standard: IEC 61000-3-3


EMS Laboratory:

  1. Electrostatic Discharge Immunity Test (ESD) — Test Standard: IEC 61000-4-2

  2. Radiated, Radio-Frequency, Electromagnetic Field Immunity Test (RS) — Test Standard: IEC 61000-4-3

  3. Immunity to Conducted Disturbances, Induced by Radio-Frequency Fields (CS) — Test Standard: IEC 61000-4-6

  4. Electrical Fast Transient/Burst Immunity Test (EFT) — Test Standard: IEC 61000-4-4

  5. Surge Immunity Test (SURGE) — Test Standard: IEC 61000-4-5

  6. Voltage Dips, Short Interruptions and Voltage Variations Immunity Tests (DIP) — Test Standard: IEC 61000-4-11

  7. Power Frequency Magnetic Field Immunity Test (PFMF) — Test Standard: IEC 61000-4-8

JJR LAB provides technical services for corporate products, including pre-compliance testing, problem rectification, and certification. We resolve relevant technical issues after a product is designed, ensuring it meets the corresponding electromagnetic compatibility standards and obtains certification as quickly as possible.

The experts at JJR LAB have years of experience working in professional laboratories on EMC, safety regulations, and lightning protection countermeasures. They are highly familiar with the component costs added during the countermeasure process and can provide rapid, efficient, and low-cost rectification solutions for corporate products in a short period. This ensures low costs during mass production and maximizes the client's benefits.


Rectification Services

  • Electromagnetic Interference (EMI) Issue Rectification Service

  • Electromagnetic Susceptibility (EMS) Issue Rectification Service

  • Single-board PCB EMC Design Service

  • Engineering Application Interference (EMI) Issue Rectification Service

  • Engineering Application Anti-interference (EMS) Issue Rectification Service

  • Product emc testing Service

  • Product EMC Certification Service


Rectification Approach

The 966 Fully Anechoic Chamber takes a comprehensive approach from the perspective of the product system. By conducting detailed analyses of the product's schematic diagrams, PCB, and structure, we solve EMC issues at the source. This ensures we provide enterprises with fast, efficient, low-cost, and mass-producible rectification solutions, thereby enhancing the client's benefits.



Email:hello@jjrlab.com


Leave Your Message


Write your message here and send it to us


Related News
Read More >>
966 Fully Anechoic Chamber 966 Fully Anechoic Chamber
07 .04.2026
At JJR LAB, our 966 Fully Anechoic Chamber provides expert EMC testing to EN55032 and IEC 61000 stan...
Power Adapter UL1310 Certification Power Adapter UL1310 Certification
07 .03.2026
JJR LAB provides professional UL1310 testing standard certification for Class 2 power adapters and c...
Standard for Air Conditioners and Dehumidifiers: I Standard for Air Conditioners and Dehumidifiers: I
07 .03.2026
JJR LAB provides expert testing for the new IEC 60335-2-40:2024 standard. Ed 8 updates safety rules ...
Guide to Children's Product Safety and Compliance Guide to Children's Product Safety and Compliance
07 .01.2026
Ensure children‘s product safety and compliance for toys and apparel by meeting strict testing stand...
US Mattress Compliance Certification US Mattress Compliance Certification
07 .01.2026
US Mattress Compliance Certification by JJR Lab: Products must meet 16 CFR 1632 & 1633 standards...
Canadian Site Mattress Compliance Testing Canadian Site Mattress Compliance Testing
06 .30.2026
Canadian site mattress compliance testing: JJR Laboratory provides mattress testing to SOR/2016-183 ...
Compliance for US Lithium-Battery-Powered Househol Compliance for US Lithium-Battery-Powered Househol
06 .30.2026
USA lithium-battery household appliance compliance: JJR Lab provides tests to UL 499, UL 1017, UL 98...
Canada Lithium Battery Home Appliances Compliance Canada Lithium Battery Home Appliances Compliance
06 .30.2026
Canada Lithium Battery Home Appliances Compliance: JJR Lab provides CSA, UL 1642/2054, CSA 62133-2 a...

Leave Your Message