EMC China Lab

966 Fully Anechoic Chamber

Views :
Update time : 2026-07-04

Radiated Emission (RE) mainly refers to the phenomenon where energy is emitted from a source into space in the form of electromagnetic waves and propagates through space, causing interference to equipment in the surrounding environment.


The 966 Fully Anechoic Chamber Electromagnetic Compatibility (EMC) Laboratory features a 3-meter anechoic chamber, uniquely capable of converting between fully and semi-anechoic configurations. The testing system inside the chamber is provided by the renowned German company R&S (Rohde & Schwarz) and comes equipped with a comprehensive suite of emc testing software. Specifically for mobile phone clients, we offer specialized testing instruments and corresponding supporting software for mobile phone spurious emissions. Additionally, the complete set of EMS (Electromagnetic Susceptibility) equipment in the laboratory is supplied by HTEC, ensuring stable performance and accurate data.


Our current testing capabilities and the test standards we meet include:

EMI Laboratory:

  1. radiated emission test (RE) — Test Standard: en55032

  2. Conducted Emission Test (CE) — Test Standard: EN55032

  3. Harmonic Current Test (Harmonic) — Test Standard: iec 61000-3-2

  4. Voltage Fluctuation and Flicker Test (Flicker) — Test Standard: IEC 61000-3-3


EMS Laboratory:

  1. Electrostatic Discharge Immunity Test (ESD) — Test Standard: IEC 61000-4-2

  2. Radiated, Radio-Frequency, Electromagnetic Field Immunity Test (RS) — Test Standard: IEC 61000-4-3

  3. Immunity to Conducted Disturbances, Induced by Radio-Frequency Fields (CS) — Test Standard: IEC 61000-4-6

  4. Electrical Fast Transient/Burst Immunity Test (EFT) — Test Standard: IEC 61000-4-4

  5. Surge Immunity Test (SURGE) — Test Standard: IEC 61000-4-5

  6. Voltage Dips, Short Interruptions and Voltage Variations Immunity Tests (DIP) — Test Standard: IEC 61000-4-11

  7. Power Frequency Magnetic Field Immunity Test (PFMF) — Test Standard: IEC 61000-4-8

JJR LAB provides technical services for corporate products, including pre-compliance testing, problem rectification, and certification. We resolve relevant technical issues after a product is designed, ensuring it meets the corresponding electromagnetic compatibility standards and obtains certification as quickly as possible.

The experts at JJR LAB have years of experience working in professional laboratories on EMC, safety regulations, and lightning protection countermeasures. They are highly familiar with the component costs added during the countermeasure process and can provide rapid, efficient, and low-cost rectification solutions for corporate products in a short period. This ensures low costs during mass production and maximizes the client's benefits.


Rectification Services

  • Electromagnetic Interference (EMI) Issue Rectification Service

  • Electromagnetic Susceptibility (EMS) Issue Rectification Service

  • Single-board PCB EMC Design Service

  • Engineering Application Interference (EMI) Issue Rectification Service

  • Engineering Application Anti-interference (EMS) Issue Rectification Service

  • Product emc testing Service

  • Product EMC Certification Service


Rectification Approach

The 966 Fully Anechoic Chamber takes a comprehensive approach from the perspective of the product system. By conducting detailed analyses of the product's schematic diagrams, PCB, and structure, we solve EMC issues at the source. This ensures we provide enterprises with fast, efficient, low-cost, and mass-producible rectification solutions, thereby enhancing the client's benefits.



Email:hello@jjrlab.com


Leave Your Message


Write your message here and send it to us


Related News
Read More >>
What are the FCC Testing Requirements for Bluetoot What are the FCC Testing Requirements for Bluetoot
10 .02.2026
FCC Bluetooth device certification testing by China JJR Laboratory covers 47 CFR Part 15, ANSI C63.1...
Australia RCM Certification for Radio Devices Australia RCM Certification for Radio Devices
10 .01.2026
Australia RCM certification for radio devices by China JJR Laboratory covers AS/NZS 4268, CISPR 32, ...
RED Cybersecurity EN 18031 Standard RED Cybersecurity EN 18031 Standard
10 .01.2026
RED Cybersecurity EN 18031 testing by China JJR Lab covers EN 18031-1/-2/-3, RED 3.3(d/e/f), CE comp...
Compliance Testing for EMC Compliance Testing for EMC
10 .01.2026
Compliance Testing for EMC by China JJR Laboratory covers CE, FCC, ISED, RCM, MIC and KC standards, ...
What is Amazon Toy Compliance? What is Amazon Toy Compliance?
09 .30.2026
Amazon Toy Compliance Testing by JJR Laboratory covers ASTM F963-23, CPSIA and EN 71 standards, help...
What is Cytotoxicity ISO 10993-5 What is Cytotoxicity ISO 10993-5
09 .29.2026
ISO 10993-5 cytotoxicity testing at JJR LAB uses cell culture hardware and analyzers to measure cell...
What is Hemocompatibility Testing ISO 10993? What is Hemocompatibility Testing ISO 10993?
09 .29.2026
ISO 10993-4 hemocompatibility testing uses blood-contact test systems, flow probes and analyzers to ...
What is ISO 10993-5 Tests for In Vitro Cytotoxicit What is ISO 10993-5 Tests for In Vitro Cytotoxicit
09 .29.2026
ISO 10993-5 cytotoxicity testing at JJR LAB uses L929 cells, MTT hardware and extraction methods to ...

Leave Your Message