UL1310 applies to power supplies or chargers powered by an AC power grid with a phase voltage not exceeding 150V, and an energy level not higher than Class 2. Under any load conditions, its input power shall not exceed 660W.
Circuit Diagram and PCB Layout Diagram: The front and back component sides, as well as the routing diagrams, must be provided separately.
Transformer and Primary Inductor Specifications: The pin configurations in the transformer specifications must strictly match the circuit diagram and the actual physical sample.
Enclosure Dimension Drawing: The overall dimensions (length, width, and height) and the units of measurement must be clearly marked.
Electronic Label: Must include the UL logo, product information, and other relevant details.
Critical Components List (CCL) or BOM (Bill of Materials).
Description of Differences Between Series Models: A detailed explanation of the differences in components across the series.
Insulator and Heatsink Dimension Drawings: If there is adhesive tape on the heatsink, the dimensions and placement of the tape on the heatsink must be clearly indicated.
Leakage Current Test
Leakage Current and Dielectric Voltage-Withstand Test under Moisture Exposure
Maximum Output Voltage Test
Maximum Input Test
Output Current and Power Test
Calibration Test of Overload Protection Devices
Full-Load Output Current Test
Normal Temperature Test
Dielectric Voltage-Withstand Test
Endurance Test of Over-temperature and Overload Protection Devices
Load and Endurance Test of Switches and Control Devices
Secondary Switch Overload Test
Operation Test
Abnormal Operation Test
Insulating Material Test
Strain Relief Test
Direct Plug-in Blade Secureness Test
Direct Plug-in Secureness Test for Input Contacts
Output Connector Safety Test
Abuse Test
Bonding Conductor Test
What Are the Types of PTCRB Certification?
PTCRB Test Certification Category Classification
What is US Operator PTCRB Certification?
Introduction to PTCRB Certification
What is PTCRB Certification
What is UL 499 Certification
Amazon UL499 Standard Test Report
Heating Lamp ETL Certification UL 499 Testing
24-hour online customer service at any time to respond, so that you worry!