EMC China Lab

CE/RED/FCC Certification Testing of IoT Devices

Views :
Update time : 2025-07-11

To ensure communication compatibility and stability of IoT terminals in a test environment, this document outlines the applicable device types, configuration requirements, and debugging procedures for prototypes using LTE-Cat M or LTE-Cat NB technologies when connecting to comprehensive testers such as the CMW500. Relevant parties are advised to carefully verify the prototype configuration prior to submission to ensure smooth testing.

 

Applicable Product Types

IoT devices utilizing LTE-Cat Mor LTE-Cat NBtechnologies.

 

Prototype Requirements

a. Prototypes with a Physical SIM Slot

No special requirements; can connect directly to the tester.

 

b. Prototypes with eSIM

The eSIM's PLMN, APN, and authentication settings must match those of the test equipment.

 

Example: CMW500 tester configuration:

 

1. PLMN: 00101

2. APN: cmw500.rohde-schwarz.com

3. Authentication: 0001 0203 0405 0607 0809 0A0B 0C0D 0E0F

 

If a physical SIM slot is used in place of the eSIM, the above settings must still align with the tester.

 

c. Prototypes with Both a Physical SIM Slot and eSIM

Instructions must be provided on how to switch between the physical SIM and eSIM for communication.

 

d. Other Types of Prototypes

Detailed information must be provided in advance and confirmed with the lab’s testing engineers.

 

Prototype Debugging

If the prototype fails to communicate with the CMW500 tester, the client must provide the following support materials:

 

1. User manual

2. Permission to access the AT command port

 

This allows inspection of the prototype status via AT commands. Common AT commands include:

 

`AT+CPIN?`

1. Function: Check if the SIM card is recognized

2. Return Value: “Ready” indicates the SIM card is properly inserted and operational

3. Example:

 CE/RED/FCC Certification Testing of IoT Devices(图1)

`AT+CIMI`

 

1. Function: Retrieve the first 5 digits of the SIM’s IMSI (i.e., PLMN)

2. Requirement: This value must match the tester’s PLMN

3. Example:

 CE/RED/FCC Certification Testing of IoT Devices(图2)

`AT+COPS?`

 

1. Function: Check network registration status

2. Return Value: "0" indicates automatic network search; if registered, returns a response like `+COPS: 0,0,00101`

3. Example:

 CE/RED/FCC Certification Testing of IoT Devices(图3)

`AT+URAT?`

Function: Display the current network mode

 

China JJR Laboratory offers CE/RED/fcc certification testing for IoT devices— inquiries are welcome.


Email:hello@jjrlab.com


Leave Your Message


Write your message here and send it to us


Related News
Read More >>
Amazon US & Canada Laser Pointer Compliance Amazon US & Canada Laser Pointer Compliance
05 .25.2026
US & Canada Amazon removes non-compliant laser listings after July 3, 2026. JJR provides FDA 21 ...
What Exactly Does IOR Registration Verification In What Exactly Does IOR Registration Verification In
05 .23.2026
CBP 9H and IOR verification may block clearance and cancel BONDs due to inconsistent importer data. ...
What is IOR? What is a Bond? What is IOR? What is a Bond?
05 .22.2026
US formal imports over $2,500 require an IOR and customs bond for compliant customs clearance. China...
What is IOR Qualification? US Customs Clearance Re What is IOR Qualification? US Customs Clearance Re
05 .22.2026
What is IOR Qualification? US Customs now requires real IOR entities for clearance. JJR LAB provides...
Amazon Toys TIC Direct Validation Amazon Toys TIC Direct Validation
05 .22.2026
Amazon Toys TIC Direct Validation: JJR offers EN71/UKCA/EN62115 test & validation, fee varies; t...
Amazon US Lithium Battery TIC Direct Validation (D Amazon US Lithium Battery TIC Direct Validation (D
05 .22.2026
Amazon US Li-batt TIC DV: TIC submits rpts; seller no upload. UL2054/1642/62133/IEC62133. JJR LAB: t...
US & Canada Marketplaces Lithium Battery Compl US & Canada Marketplaces Lithium Battery Compl
05 .22.2026
US & Canada Lithium Battery Compliance | JJR: UL1642/2054/62133-2 & UN38.3 Amazon. Tests: sh...
PPWR Hazardous Substances Control, Recyclability, PPWR Hazardous Substances Control, Recyclability,
05 .21.2026
PPWR Hazardous Substances, Recyclability & Labeling | JJR PPWR (2025/40)tests heavy metals PFAS ...

Leave Your Message