JJRLAB laboratory is equipped with 8 electromagnetic shielding rooms, capable of conducting electromagnetic testing for conducted emissions according to different standard limits. The detection limits of its testing methods comply with national standards, European Union regulations, and international standards such as those of the United States. The range of electronic and electrical products covers household appliances, information technology, lighting, medical devices, and rail transportation, among others. Testing turnaround time: 3-5 working days.


emc testing is the fundamental entry requirement for electronic and electrical products to enter global markets. Products exported to the European Union, the United States, Canada, Australia, South Korea, and mainland China, as well as those sold domestically, need to meet emc testing requirements. Conducted emission testing is part of EMC testing. As a pioneer and leader in third-party testing and certification services in China, JJRLAB provides comprehensive solutions including testing, calibration, inspection, certification, and technical services to enterprises worldwide.

 

Conducted Emission Testing China Laboratory(图1)

Applicable Countries and Testing Standards

1. China  

   - GB 4343.1 Electromagnetic Compatibility Requirements for Household Appliances, Electric Tools, and Similar Apparatus Part 1: Emission

   - GB 4824 Industrial, Scientific, and Medical (ISM) Radio-Frequency Equipment Radio Disturbance Characteristics Limits and Measurement Methods

   - GB/T 9254 Radio Disturbance Characteristics Limits and Measurement Methods of Information Technology Equipment

   - GB/T 13837 Radio Disturbance Characteristics Limits and Measurement Methods of Sound and Television Broadcast Receivers and Associated Equipment

   - GB/T 17743 Radio Disturbance Characteristics Limits and Measurement Methods of Electrical Lighting and Similar Equipment

   - GB/T 24338.4 Electromagnetic Compatibility for Railway Applications Part 3-2: Rolling Stock Equipment

   - YY 0505 Medical Electrical Equipment Part 1-2: General Requirements for Safety and Essential Performance Collateral Standard—Electromagnetic Compatibility Requirements and Tests

 

2. European Union  

   - EN 55014-1 Electromagnetic Compatibility Requirements for Household Appliances, Electric Tools, and Similar Apparatus Part 1: Emission

   - EN 55011 Industrial, Scientific, and Medical Equipment Radio-Frequency Disturbance Characteristics Limits and Methods of Measurement

   - en 55032 Electromagnetic Compatibility of Multimedia Equipment Emission Requirements

   - EN 55015 Limits and Methods of Measurement of Radio Disturbance Characteristics of Electrical Lighting and Similar Equipment

   - EN 50121-3-2 Railway Applications Electromagnetic Compatibility Part 3-2: Rolling Stock Apparatus

   - EN 60601-1-2 Medical Electrical Equipment General Requirements for Basic Safety and Essential Performance Collateral Standard—Electromagnetic Disturbances Requirements and Tests

 

3. United States  

   - fcc PART15 Radio Frequency Devices

   - FCC PART18 Industrial, Scientific, and Medical Equipment

 

4. Canada  

   - ICES-001 Industrial, Scientific, and Medical (ISM) Equipment

   - ICES-003 Information Technology Equipment (Including Digital Apparatus) Limits and Methods of Measurement

   - ICES-005 Lighting Equipment

 

5. Australia  

   - AS CISPR 14.1 Electromagnetic Compatibility Requirements for Household Appliances, Electric Tools, and Similar Apparatus Emission

   - AS CISPR 11 Industrial, Scientific, and Medical Equipment Radio-Frequency Disturbance Characteristics Limits and Methods of Measurement

   - as/nzs cispr 32 Electromagnetic Compatibility of Multimedia Equipment Emission Requirements

   - AS CISPR 15 Limits and Methods of Measurement of Radio Disturbance Characteristics of Electrical Lighting and Similar Equipment

 

Applicable Product Range

Electronic and electrical products including large household appliances, small household appliances, information technology and communication equipment, consumer electronics, lighting equipment, electrical and electronic tools, toys, leisure and sports equipment, medical devices, monitoring equipment, vending machines, and other electronic and electrical equipment.

 

General Sample Requirements

Typically, 1-2 normal samples are required. For specific details, please consult JJRLAB's online customer service.


Email:hello@jjrlab.com


Leave Your Message


Write your message here and send it to us


Related News
Read More >>
Electronic Products Safety Testing Laboratory Electronic Products Safety Testing Laboratory
09 .10.2026
Choose JJR LAB for electronic product safety testing. We ensure compliance with IEC/EN standards (60...
HAC Hearing Aid Compatibility Testing HAC Hearing Aid Compatibility Testing
09 .10.2026
JJR LAB offers expert hearing aid compatibility (HAC) services meeting FCC testing standards. Get fa...
Wireless Electronic Product SAR Testing Services Wireless Electronic Product SAR Testing Services
09 .10.2026
JJR Lab offers expert SAR testing services for wireless electronics. Ensure fast global compliance w...
How to Choose an EMC Test Laboratory How to Choose an EMC Test Laboratory
09 .10.2026
How to choose an EMC test laboratory? JJR Lab provides professional EMI and EMS services meeting glo...
What is RF Testing What is RF Testing
09 .09.2026
Wondering what is RF testing? JJR Laboratory provides expert radio frequency testing services to ens...
How to get MEID Address How to get MEID Address
09 .09.2026
Discover how to obtain your 56-bit Mobile Equipment Identifier (MEID). Learn its format, importance ...
How to get a MAC Address How to get a MAC Address
09 .09.2026
Learn how to obtain a MAC address for your network devices. JJR Lab provides expert IEEE MAC applica...
How to get an IMEI Number How to get an IMEI Number
09 .09.2026
Learn how to obtain an IMEI number for mobile devices with China JJR Laboratory. Understand the 15-d...

Leave Your Message