ITE refers to equipment whose main function is the input, storage, display, retrieval, transmission, processing, exchange, or control of data and telecommunication messages (or combinations of these).
1. May have one or more terminal ports for information transmission
2. Rated voltage does not exceed 600V
1. Personal computers
2. Laptops
3. Tablet PCs
4. Mice
5. Keyboards
6. Monitors
7. All-in-one computers
8. Printers
9. Projectors
10. Routers
11. Scanners
12. USB drives
13. External hard drives
14. Computer peripherals and accessories
1. EN55022
2. EN55024
3. en61000-3-2
4. EN61000-3-3
2004/108/EC
1. Power line conducted emission: 0.15–300 MHz (EN55022)
2. Telecom port conducted emission: 0.15–300 MHz (EN55022)
3. Radiated emission: 300 Hz–66 GHz (EN55022)
1. ≤ 108 MHz: test up to 1 GHz
2. 108–500 MHz: test up to 2 GHz
3. 500 MHz–1 GHz: test up to 5 GHz
4. > 1 GHz: test up to 5× highest frequency or 66 GHz, whichever is lower
1. AC220–240V
2. Required for equipment >75W
3. No limit and no test for equipment ≤75W
1. AC220–240V
2. Pst ≤ 1.0
3. Plt ≤ 0.65
4. dc ≤ 3.3%
5. Max relative voltage change ≤ 4%
1. Electrostatic discharge: ±4kV contact, ±8kV air (Performance A)
2. Radiated susceptibility: 80 MHz–1 GHz (Performance A)
3. Electrical fast transient: 1kV AC power, 0.5kV DC power, 0.5kV signal/telecom (Performance B)
4. Surge: 1kV line-line, 2kV line-earth (AC); 0.5kV (DC); telecom 1kV or 4kV depending on protection (Performance B)
5. Conducted susceptibility, magnetic field, voltage dips: as per EN55024
A: Operates normally during disturbance
B: Temporary degradation allowed, recovers automatically
C: Function loss allowed, recoverable, no loss of non-volatile data
Standard:FCC 47CFR Part 15B
Certification Type:FCC DOC
1. Power line conducted: 0.15–30 MHz
2. Radiated emission: 30 MHz–40 GHz
1. 1.705–108 MHz: up to 1 GHz
2. 108–500 MHz: up to 2 GHz
3. 500 MHz–1 GHz: up to 5 GHz
4. > 1 GHz: up to 5× highest frequency or 40 GHz
Standard:ICES-003
Same test items and frequency range as FCC
Standards:GB9254, GB17625.1
1. Power line conducted: 0.15–30 MHz
2. Telecom port conducted: 0.15–30 MHz
3. Radiated emission: 30 MHz–6 GHz
1. ≤ 108 MHz: up to 1 GHz
2. 108–500 MHz: up to 2 GHz
3. 500 MHz–1 GHz: up to 5 GHz
4. > 1 GHz: up to 5× highest frequency or 6 GHz
1. Required for AC220–240V products >75W
2. No limit or test required for ≤75W
Standard:AS/NZS CISPR22
1. Power line conducted: 0.15–30 MHz
2. Telecom port conducted: 0.15–30 MHz
3. Radiated emission: 30 MHz–6 GHz
Measurement frequency:same as CCC
Standard:VCCI-V3
1. Power line conducted: 0.15–30 MHz
2. Telecom port conducted: 0.15–30 MHz
3. Radiated emission: 30 MHz–6 GHz
Measurement frequency:same as CCC
Standards:KN22, KN24
1. Power line conducted: 0.15–30 MHz
2. Telecom port conducted: 0.15–30 MHz
3. Radiated emission: 30 MHz–6 GHz
Measurement frequency:same as CCC
Standard:CNS13438
1. Power line conducted: 0.15–30 MHz
2. Telecom port conducted: 0.15–30 MHz
3. Radiated emission: 30 MHz–6 GHz
Measurement frequency:same as CCC
24-hour online customer service at any time to respond, so that you worry!