Main Reference Standards

◆ CISPR 11/EN 55011/GB 4824:

   "Industrial, Scientific, and Medical (ISM) Radio-Frequency Equipment - Electromagnetic Disturbance Characteristics - Limits and Methods of Measurement"

iec 60601-1-2/YY 0505:

   "Medical Electrical Equipment - Part 1-2: General Requirements for Safety - Collateral Standard: Electromagnetic Compatibility - Requirements and Tests"

iec 61326-1/GB T18268.1:

   "Electrical Equipment for Measurement, Control, and Laboratory Use - EMC Requirements - Part 1: General Requirements"

◆ IEC 61326-2-6/GB T18268.26:

   "Electrical Equipment for Measurement, Control, and Laboratory Use - EMC Requirements - Part 26: Specific Requirements - In Vitro Diagnostic (IVD) Equipment"

iec 61000-3-2/GB 17625.1:

   "Electromagnetic Compatibility - Limits - Limits for Harmonic Current Emissions (Equipment Input Current ≤16A per Phase)"

◆ IEC 61000-3-3/GB 17625.2:

   "Electromagnetic Compatibility - Limits - Limitation of Voltage Changes, Voltage Fluctuations, and Flicker in Public Low-Voltage Supply Systems, for Equipment with Rated Current ≤16A and Subject to Conditional Connection"

 

emi test Items

◆ Conducted Disturbance Voltage, 150kHz-30MHz, Quasi-Peak/Average

◆ Radiated Disturbance (Magnetic Field), 9kHz-30MHz, Quasi-Peak

◆ Radiated Disturbance (Electric Field), 150kHz-1GHz, Quasi-Peak; 1GHz-18GHz, Peak/Weighted

◆ Harmonic Current Emission Test, According to IEC 61000-3-2

◆ Voltage Fluctuation and Flicker Test, According to IEC 61000-3-3

 

EMS Test Items

◆ Electrostatic Discharge Immunity, Contact Discharge 6kV, Air Discharge 8kV

◆ Radiated Radio-Frequency Electromagnetic Field Immunity, Maximum Test Field Strength 10V/m

◆ Electrical Fast Transient/Burst Immunity, Maximum Test Level 2kV

◆ Surge Immunity, Maximum Test Level 2kV

◆ Radio-Frequency Conducted Immunity, Maximum Test Level 10V

◆ Power Frequency Magnetic Field Immunity, Maximum Test Field Strength 3A/m

◆ Voltage Dips, Short Interruptions, and Voltage Variations Immunity, According to IEC 61000-4-11


Email:hello@jjrlab.com


Leave Your Message


Write your message here and send it to us


Related News
Read More >>
Global Certification Guide for Lithium Batteries Global Certification Guide for Lithium Batteries
02 .01.2026
Lithium battery certifications in Thailand, Korea, India, Australia, and Saudi Arabia. CMS/CNAS/ISO/...
Compliance of Amazon 18650 Lithium Battery Product Compliance of Amazon 18650 Lithium Battery Product
02 .01.2026
Amazon 18650 batteries face removal; sellers must meet UN38.3, UL, FCC, MSDS standards. JJR CMS, CNA...
What is CE Certification and EU Authorized Represe What is CE Certification and EU Authorized Represe
02 .01.2026
CE Certification requires an EU Authorized Representative. JJR labs (CMS, CNAS, ISO/IEC 17025) provi...
What Are the Lithium Battery Safety Tests? What Are the Lithium Battery Safety Tests?
02 .01.2026
Lithium battery safety tests (overcharge, short-circuit, thermal, mechanical) ensure reliability; te...
What is the EN 61326-2-3 Standard? What is the EN 61326-2-3 Standard?
01 .31.2026
EN 61326-2-3 ensures EMC compliance for sensors, transmitters, lab & industrial equipment. JJR o...
Why Do Smart Sockets Need IEC 60884 Certification? Why Do Smart Sockets Need IEC 60884 Certification?
01 .31.2026
Smart sockets need IEC 60884 certification for safety & market ; JJR CNAS/ILAC/ISO17025 labs pro...
Why Retest the Device if the 5G Module Already Has Why Retest the Device if the 5G Module Already Has
01 .31.2026
Even if a 5G module is CE-certified, the whole device needs testing per EU RED; JJR LAB provides ISO...
Overview of IEC 62087 Test Standard Overview of IEC 62087 Test Standard
01 .31.2026
IEC 62087 defines power-consumption tests for TVs, monitors, audio/video devices. JJR Lab (CMS, CNAS...

Leave Your Message