Main Reference Standards

◆ CISPR 11/EN 55011/GB 4824:

   "Industrial, Scientific, and Medical (ISM) Radio-Frequency Equipment - Electromagnetic Disturbance Characteristics - Limits and Methods of Measurement"

iec 60601-1-2/YY 0505:

   "Medical Electrical Equipment - Part 1-2: General Requirements for Safety - Collateral Standard: Electromagnetic Compatibility - Requirements and Tests"

iec 61326-1/GB T18268.1:

   "Electrical Equipment for Measurement, Control, and Laboratory Use - EMC Requirements - Part 1: General Requirements"

◆ IEC 61326-2-6/GB T18268.26:

   "Electrical Equipment for Measurement, Control, and Laboratory Use - EMC Requirements - Part 26: Specific Requirements - In Vitro Diagnostic (IVD) Equipment"

iec 61000-3-2/GB 17625.1:

   "Electromagnetic Compatibility - Limits - Limits for Harmonic Current Emissions (Equipment Input Current ≤16A per Phase)"

◆ IEC 61000-3-3/GB 17625.2:

   "Electromagnetic Compatibility - Limits - Limitation of Voltage Changes, Voltage Fluctuations, and Flicker in Public Low-Voltage Supply Systems, for Equipment with Rated Current ≤16A and Subject to Conditional Connection"

 

emi test Items

◆ Conducted Disturbance Voltage, 150kHz-30MHz, Quasi-Peak/Average

◆ Radiated Disturbance (Magnetic Field), 9kHz-30MHz, Quasi-Peak

◆ Radiated Disturbance (Electric Field), 150kHz-1GHz, Quasi-Peak; 1GHz-18GHz, Peak/Weighted

◆ Harmonic Current Emission Test, According to IEC 61000-3-2

◆ Voltage Fluctuation and Flicker Test, According to IEC 61000-3-3

 

EMS Test Items

◆ Electrostatic Discharge Immunity, Contact Discharge 6kV, Air Discharge 8kV

◆ Radiated Radio-Frequency Electromagnetic Field Immunity, Maximum Test Field Strength 10V/m

◆ Electrical Fast Transient/Burst Immunity, Maximum Test Level 2kV

◆ Surge Immunity, Maximum Test Level 2kV

◆ Radio-Frequency Conducted Immunity, Maximum Test Level 10V

◆ Power Frequency Magnetic Field Immunity, Maximum Test Field Strength 3A/m

◆ Voltage Dips, Short Interruptions, and Voltage Variations Immunity, According to IEC 61000-4-11


Email:hello@jjrlab.com


Leave Your Message


Write your message here and send it to us


Related News
Read More >>
Introduction to RE, CE and ESD in EMC Testing Introduction to RE, CE and ESD in EMC Testing
04 .03.2026
JJR Lab : RE, CE and ESD ensure EMC compliance by controlling emissions and verifying immunity, so d...
EMC Testing: EMI / EMS / RE / CE / CS / ESD EMC Testing: EMI / EMS / RE / CE / CS / ESD
04 .03.2026
EMC ensures devices neither cause nor suffer interference. EMI (CE, RE) measures emissions, while EM...
Important: Latest Notice on SASO IEC 62680 Important: Latest Notice on SASO IEC 62680
04 .03.2026
SASO delays IEC 62680 enforcement to May 1, 2026; non-compliant devices lose COC eligibility. JJR LA...
What is BS EN 1388-2 Certification Testing What is BS EN 1388-2 Certification Testing
04 .03.2026
EN 1388-2 strictly limits lead/cadmium in ceramic tableware; JJR LAB tests heavy metal migration usi...
How to get a BS EN 1388-1 Compliance Report? How to get a BS EN 1388-1 Compliance Report?
04 .03.2026
Ceramic tableware must meet BS EN 1388-1 limits for lead/cadmium; tested via EN 1388-2 under simulat...
What is BS EN 1388-1 Certification Testing? What is BS EN 1388-1 Certification Testing?
04 .03.2026
BS EN 1388-1 tests ceramic foodware for lead and cadmium migration, ensuring full CE compliance and ...
What is FCC ID Used For What is FCC ID Used For
04 .02.2026
FCC ID ensures wireless devices meet US RF, SAR, and EMC safety standards; JJR Lab provides professi...
AS/NZS 4417.2:2020 Amd 1:2026 Australia and New Ze AS/NZS 4417.2:2020 Amd 1:2026 Australia and New Ze
04 .02.2026
AS/NZS 4417.2:2020 Amd 1:2026 strengthens AU/NZ electrical safety by adding categories, tightening c...

Leave Your Message