◆ CISPR 11/EN 55011/GB 4824:

   "Industrial, Scientific, and Medical (ISM) Radio-Frequency Equipment - Electromagnetic Disturbance Characteristics - Limits and Methods of Measurement"

iec 60601-1-2/YY 0505:

   "Medical Electrical Equipment - Part 1-2: General Requirements for Safety - Collateral Standard: Electromagnetic Compatibility - Requirements and Tests"

iec 61326-1/GB T18268.1:

   "Electrical Equipment for Measurement, Control, and Laboratory Use - EMC Requirements - Part 1: General Requirements"

◆ IEC 61326-2-6/GB T18268.26:

   "Electrical Equipment for Measurement, Control, and Laboratory Use - EMC Requirements - Part 26: Specific Requirements - In Vitro Diagnostic (IVD) Equipment"

iec 61000-3-2/GB 17625.1:

   "Electromagnetic Compatibility - Limits - Limits for Harmonic Current Emissions (Equipment Input Current ≤16A per Phase)"

◆ IEC 61000-3-3/GB 17625.2:

   "Electromagnetic Compatibility - Limits - Limitation of Voltage Changes, Voltage Fluctuations, and Flicker in Public Low-Voltage Supply Systems, for Equipment with Rated Current ≤16A and Subject to Conditional Connection"

 

emi test Items

◆ Conducted Disturbance Voltage, 150kHz-30MHz, Quasi-Peak/Average

◆ Radiated Disturbance (Magnetic Field), 9kHz-30MHz, Quasi-Peak

◆ Radiated Disturbance (Electric Field), 150kHz-1GHz, Quasi-Peak; 1GHz-18GHz, Peak/Weighted

◆ Harmonic Current Emission Test, According to IEC 61000-3-2

◆ Voltage Fluctuation and Flicker Test, According to IEC 61000-3-3

 

EMS Test Items

◆ Electrostatic Discharge Immunity, Contact Discharge 6kV, Air Discharge 8kV

◆ Radiated Radio-Frequency Electromagnetic Field Immunity, Maximum Test Field Strength 10V/m

◆ Electrical Fast Transient/Burst Immunity, Maximum Test Level 2kV

◆ Surge Immunity, Maximum Test Level 2kV

◆ Radio-Frequency Conducted Immunity, Maximum Test Level 10V

◆ Power Frequency Magnetic Field Immunity, Maximum Test Field Strength 3A/m

◆ Voltage Dips, Short Interruptions, and Voltage Variations Immunity, According to IEC 61000-4-11


Email:hello@jjrlab.com


Leave Your Message


Write your message here and send it to us


Related News
Read More >>
EU PPWR New Packaging Compliance EU PPWR New Packaging Compliance
09 .18.2026
Ensure EU PPWR (EU 2025/40) compliance with JJR Lab. We provide comprehensive packaging testing stan...
How to Obtain an MSDS/SDS Report How to Obtain an MSDS/SDS Report
09 .18.2026
Need a compliant MSDS/SDS report? JJR Lab provides expert chemical safety data services, ensuring yo...
CPSIA Testing Service Consulting CPSIA Testing Service Consulting
09 .18.2026
Get reliable CPSIA testing for children‘s toys at JJR Lab. We are a CPSC-accredited facility testing...
Food Contact Materials Testing Services Food Contact Materials Testing Services
09 .18.2026
JJR Lab provides expert food contact materials testing services. Ensure global compliance with FDA, ...
California 65 Testing Service Consultation California 65 Testing Service Consultation
09 .17.2026
Choose JJR Lab for reliable California 65 testing services. We ensure your products strictly comply ...
REACH Chemical Testing Services REACH Chemical Testing Services
09 .17.2026
Ensure EU compliance with JJR Lab‘s REACH chemical testing services. We deliver expert SVHC testing ...
Electronic Vaporizers EU TPD / US PMTA / UK MHRA Electronic Vaporizers EU TPD / US PMTA / UK MHRA
09 .17.2026
JJR Lab provides expert electronic vaporizer testing to global standards like GB 41700, ensuring EU ...
ISO 10993 Biocompatibility Standards ISO 10993 Biocompatibility Standards
09 .16.2026
Ensure medical device safety and global compliance with JJR Lab. We provide expert ISO 10993 biocomp...

Leave Your Message