Main Reference Standards

◆ CISPR 11/EN 55011/GB 4824:

   "Industrial, Scientific, and Medical (ISM) Radio-Frequency Equipment - Electromagnetic Disturbance Characteristics - Limits and Methods of Measurement"

◆ iec 60601-1-2/YY 0505:

   "Medical Electrical Equipment - Part 1-2: General Requirements for Safety - Collateral Standard: Electromagnetic Compatibility - Requirements and Tests"

◆ iec 61326-1/GB T18268.1:

   "Electrical Equipment for Measurement, Control, and Laboratory Use - EMC Requirements - Part 1: General Requirements"

◆ IEC 61326-2-6/GB T18268.26:

   "Electrical Equipment for Measurement, Control, and Laboratory Use - EMC Requirements - Part 26: Specific Requirements - In Vitro Diagnostic (IVD) Equipment"

◆ iec 61000-3-2/GB 17625.1:

   "Electromagnetic Compatibility - Limits - Limits for Harmonic Current Emissions (Equipment Input Current ≤16A per Phase)"

◆ IEC 61000-3-3/GB 17625.2:

   "Electromagnetic Compatibility - Limits - Limitation of Voltage Changes, Voltage Fluctuations, and Flicker in Public Low-Voltage Supply Systems, for Equipment with Rated Current ≤16A and Subject to Conditional Connection"

 

emi test Items

◆ Conducted Disturbance Voltage, 150kHz-30MHz, Quasi-Peak/Average

◆ Radiated Disturbance (Magnetic Field), 9kHz-30MHz, Quasi-Peak

◆ Radiated Disturbance (Electric Field), 150kHz-1GHz, Quasi-Peak; 1GHz-18GHz, Peak/Weighted

◆ Harmonic Current Emission Test, According to IEC 61000-3-2

◆ Voltage Fluctuation and Flicker Test, According to IEC 61000-3-3

 

EMS Test Items

◆ Electrostatic Discharge Immunity, Contact Discharge 6kV, Air Discharge 8kV

◆ Radiated Radio-Frequency Electromagnetic Field Immunity, Maximum Test Field Strength 10V/m

◆ Electrical Fast Transient/Burst Immunity, Maximum Test Level 2kV

◆ Surge Immunity, Maximum Test Level 2kV

◆ Radio-Frequency Conducted Immunity, Maximum Test Level 10V

◆ Power Frequency Magnetic Field Immunity, Maximum Test Field Strength 3A/m

◆ Voltage Dips, Short Interruptions, and Voltage Variations Immunity, According to IEC 61000-4-11


Email:hello@jjrlab.com


Leave Your Message


Write your message here and send it to us


Related News
Read More >>
What is 16 CFR 1260 Compliance for Window Covering What is 16 CFR 1260 Compliance for Window Covering
11 .11.2026
Get 16 CFR 1260 compliance testing for custom window coverings at JJR Laboratory. ISO/IEC 17025 accr...
Differences Between F2923 and F2999 Differences Between F2923 and F2999
11 .11.2026
Need ASTM F2923 & F2999 testing for US Amazon jewelry compliance? JJR LAB is a CMA & CNAS ac...
How to get the FMVSS No.108 Test Report for Car Li How to get the FMVSS No.108 Test Report for Car Li
11 .11.2026
Obtain your FMVSS 108 test report for car lights with JJR Lab. As an ISO/IEC 17025, CMA, and CNAS ac...
What is Motorcycle Helmet FMVSS No. 218 Compliance What is Motorcycle Helmet FMVSS No. 218 Compliance
11 .11.2026
Ensure Amazon US/Canada motorcycle helmet FMVSS 218 compliance with JJR Laboratory. We offer trusted...
Amazon Baby Crib TIC Verification Amazon Baby Crib TIC Verification
11 .11.2026
Get Amazon Baby Crib TIC verification with JJR LAB. We provide ISO/IEC 17025, CMA, and CNAS accredit...
Amazon TIC Verification for Cribs with Changing Ta Amazon TIC Verification for Cribs with Changing Ta
11 .11.2026
Amazon TIC verification for cribs with changing tables! JJR LAB offers ISO/IEC 17025 accredited, CMA...
How to get an Amazon 16 CFR 1243 Test Report? How to get an Amazon 16 CFR 1243 Test Report?
11 .10.2026
Need an Amazon 16 CFR 1243 test report for infant support cushions? Contact JJR LAB, a CMA & CNA...
Infant Support Cushions 16 CFR 1243 2026 Infant Support Cushions 16 CFR 1243 2026
11 .10.2026
Ensure 16 CFR 1243 compliance for infant support cushions. JJR Lab offers CMA & CNAS accredited ...

Leave Your Message