EMC China Lab

Medical Device EMC Test Items & Standards

Views :
Update time : 2024-04-26

Main Reference Standards

◆ CISPR 11/EN 55011/GB 4824:

   "Industrial, Scientific, and Medical (ISM) Radio-Frequency Equipment - Electromagnetic Disturbance Characteristics - Limits and Methods of Measurement"

iec 60601-1-2/YY 0505:

   "Medical Electrical Equipment - Part 1-2: General Requirements for Safety - Collateral Standard: Electromagnetic Compatibility - Requirements and Tests"

iec 61326-1/GB T18268.1:

   "Electrical Equipment for Measurement, Control, and Laboratory Use - EMC Requirements - Part 1: General Requirements"

◆ IEC 61326-2-6/GB T18268.26:

   "Electrical Equipment for Measurement, Control, and Laboratory Use - EMC Requirements - Part 26: Specific Requirements - In Vitro Diagnostic (IVD) Equipment"

iec 61000-3-2/GB 17625.1:

   "Electromagnetic Compatibility - Limits - Limits for Harmonic Current Emissions (Equipment Input Current ≤16A per Phase)"

◆ IEC 61000-3-3/GB 17625.2:

   "Electromagnetic Compatibility - Limits - Limitation of Voltage Changes, Voltage Fluctuations, and Flicker in Public Low-Voltage Supply Systems, for Equipment with Rated Current ≤16A and Subject to Conditional Connection"

 

emi test Items

◆ Conducted Disturbance Voltage, 150kHz-30MHz, Quasi-Peak/Average

◆ Radiated Disturbance (Magnetic Field), 9kHz-30MHz, Quasi-Peak

◆ Radiated Disturbance (Electric Field), 150kHz-1GHz, Quasi-Peak; 1GHz-18GHz, Peak/Weighted

◆ Harmonic Current Emission Test, According to IEC 61000-3-2

◆ Voltage Fluctuation and Flicker Test, According to IEC 61000-3-3

 

EMS Test Items

◆ Electrostatic Discharge Immunity, Contact Discharge 6kV, Air Discharge 8kV

◆ Radiated Radio-Frequency Electromagnetic Field Immunity, Maximum Test Field Strength 10V/m

◆ Electrical Fast Transient/Burst Immunity, Maximum Test Level 2kV

◆ Surge Immunity, Maximum Test Level 2kV

◆ Radio-Frequency Conducted Immunity, Maximum Test Level 10V

◆ Power Frequency Magnetic Field Immunity, Maximum Test Field Strength 3A/m

◆ Voltage Dips, Short Interruptions, and Voltage Variations Immunity, According to IEC 61000-4-11


Email:hello@jjrlab.com


Leave Your Message


Write your message here and send it to us


Related News
Read More >>
Global Export Certification Standards for Electric Global Export Certification Standards for Electric
07 .17.2026
Exporting electric fans globally requires CE, FCC, UL, and CCC certifications. Key standards: IEC/EN...
U.S. CPSC Consumer Product Standards & Require U.S. CPSC Consumer Product Standards & Require
07 .17.2026
US CPSC regulations ensure consumer product safety through strict test standards like 16 CFR and AST...
US Baby Diaper Changing Table ASTM F2388-21 / 16 C US Baby Diaper Changing Table ASTM F2388-21 / 16 C
07 .17.2026
To sell US baby diaper changing tables on Amazon, products must pass ASTM F2388-21 and 16 CFR 1235 s...
Baby Bath Towel US CPC & 16 CFR 1610 Flammabil Baby Bath Towel US CPC & 16 CFR 1610 Flammabil
07 .17.2026
US CPC certification for baby bath towels requires 16 CFR 1610 flammability and CPSIA testing. JJR L...
Amazon US Humidifier UL998 Testing + DV/TIC Amazon US Humidifier UL998 Testing + DV/TIC
07 .17.2026
Amazon US requires all humidifiers to pass the UL998 testing standard and DV audits to avoid delisti...
Amazon Small Appliances TIC DV Mandatory Review Amazon Small Appliances TIC DV Mandatory Review
07 .16.2026
Amazon mandates TIC DV review for lithium small appliances. JJR LAB provides complete testing (UL507...
What is the UL 1017 Test Standard What is the UL 1017 Test Standard
07 .16.2026
The UL 1017 test standard ensures vacuum cleaner safety by validating electrical, fire, and mechanic...
UL 1017 Electric Vacuum Cleaner Testing Items UL 1017 Electric Vacuum Cleaner Testing Items
07 .16.2026
The UL 1017 standard ensures vacuum cleaner safety by testing electrical, mechanical, and fire risks...

Leave Your Message