◆ CISPR 11/EN 55011/GB 4824:

   "Industrial, Scientific, and Medical (ISM) Radio-Frequency Equipment - Electromagnetic Disturbance Characteristics - Limits and Methods of Measurement"

iec 60601-1-2/YY 0505:

   "Medical Electrical Equipment - Part 1-2: General Requirements for Safety - Collateral Standard: Electromagnetic Compatibility - Requirements and Tests"

iec 61326-1/GB T18268.1:

   "Electrical Equipment for Measurement, Control, and Laboratory Use - EMC Requirements - Part 1: General Requirements"

◆ IEC 61326-2-6/GB T18268.26:

   "Electrical Equipment for Measurement, Control, and Laboratory Use - EMC Requirements - Part 26: Specific Requirements - In Vitro Diagnostic (IVD) Equipment"

iec 61000-3-2/GB 17625.1:

   "Electromagnetic Compatibility - Limits - Limits for Harmonic Current Emissions (Equipment Input Current ≤16A per Phase)"

◆ IEC 61000-3-3/GB 17625.2:

   "Electromagnetic Compatibility - Limits - Limitation of Voltage Changes, Voltage Fluctuations, and Flicker in Public Low-Voltage Supply Systems, for Equipment with Rated Current ≤16A and Subject to Conditional Connection"

 

emi test Items

◆ Conducted Disturbance Voltage, 150kHz-30MHz, Quasi-Peak/Average

◆ Radiated Disturbance (Magnetic Field), 9kHz-30MHz, Quasi-Peak

◆ Radiated Disturbance (Electric Field), 150kHz-1GHz, Quasi-Peak; 1GHz-18GHz, Peak/Weighted

◆ Harmonic Current Emission Test, According to IEC 61000-3-2

◆ Voltage Fluctuation and Flicker Test, According to IEC 61000-3-3

 

EMS Test Items

◆ Electrostatic Discharge Immunity, Contact Discharge 6kV, Air Discharge 8kV

◆ Radiated Radio-Frequency Electromagnetic Field Immunity, Maximum Test Field Strength 10V/m

◆ Electrical Fast Transient/Burst Immunity, Maximum Test Level 2kV

◆ Surge Immunity, Maximum Test Level 2kV

◆ Radio-Frequency Conducted Immunity, Maximum Test Level 10V

◆ Power Frequency Magnetic Field Immunity, Maximum Test Field Strength 3A/m

◆ Voltage Dips, Short Interruptions, and Voltage Variations Immunity, According to IEC 61000-4-11


Email:hello@jjrlab.com


Leave Your Message


Write your message here and send it to us


Related News
Read More >>
What is the UL998 Testing Process for Household Hu What is the UL998 Testing Process for Household Hu
07 .18.2026
To list humidifiers on US platforms, compliance with the UL998 testing standard is mandatory for saf...
Children's Rubik's Cube US CPC Certification Stand Children's Rubik's Cube US CPC Certification Stand
07 .18.2026
Exporting children‘s Rubik‘s cubes to the US requires a CPC. JJR LAB provides testing for core stand...
US Magnet Products 16 CFR 1262 Regulation GCC Cert US Magnet Products 16 CFR 1262 Regulation GCC Cert
07 .18.2026
US CPSC mandates a GCC for magnet products via 16 CFR 1262 or ASTM F963 standards (flux <50 kG²mm...
Required Certifications for EU Balloon Exports: EN Required Certifications for EU Balloon Exports: EN
07 .18.2026
Exporting balloons to the EU requires CE marks. JJR LAB provides complete EN71-1, EN71-2, EN71-3, an...
Amazon Canada Baby Bottles and Teats SOR/2016-180 Amazon Canada Baby Bottles and Teats SOR/2016-180
07 .18.2026
JJR LAB provides compliance testing for Amazon Canada baby feeding products (SOR/2016-180 for nipple...
Global Export Certification Standards for Electric Global Export Certification Standards for Electric
07 .17.2026
Exporting electric fans globally requires CE, FCC, UL, and CCC certifications. Key standards: IEC/EN...
U.S. CPSC Consumer Product Standards & Require U.S. CPSC Consumer Product Standards & Require
07 .17.2026
US CPSC regulations ensure consumer product safety through strict test standards like 16 CFR and AST...
US Baby Diaper Changing Table ASTM F2388-21 / 16 C US Baby Diaper Changing Table ASTM F2388-21 / 16 C
07 .17.2026
To sell US baby diaper changing tables on Amazon, products must pass ASTM F2388-21 and 16 CFR 1235 s...

Leave Your Message