EMC China Lab

Medical Device EMC Test Items & Standards

Views :
Update time : 2024-04-26

Main Reference Standards

◆ CISPR 11/EN 55011/GB 4824:

   "Industrial, Scientific, and Medical (ISM) Radio-Frequency Equipment - Electromagnetic Disturbance Characteristics - Limits and Methods of Measurement"

iec 60601-1-2/YY 0505:

   "Medical Electrical Equipment - Part 1-2: General Requirements for Safety - Collateral Standard: Electromagnetic Compatibility - Requirements and Tests"

iec 61326-1/GB T18268.1:

   "Electrical Equipment for Measurement, Control, and Laboratory Use - EMC Requirements - Part 1: General Requirements"

◆ IEC 61326-2-6/GB T18268.26:

   "Electrical Equipment for Measurement, Control, and Laboratory Use - EMC Requirements - Part 26: Specific Requirements - In Vitro Diagnostic (IVD) Equipment"

iec 61000-3-2/GB 17625.1:

   "Electromagnetic Compatibility - Limits - Limits for Harmonic Current Emissions (Equipment Input Current ≤16A per Phase)"

◆ IEC 61000-3-3/GB 17625.2:

   "Electromagnetic Compatibility - Limits - Limitation of Voltage Changes, Voltage Fluctuations, and Flicker in Public Low-Voltage Supply Systems, for Equipment with Rated Current ≤16A and Subject to Conditional Connection"

 

emi test Items

◆ Conducted Disturbance Voltage, 150kHz-30MHz, Quasi-Peak/Average

◆ Radiated Disturbance (Magnetic Field), 9kHz-30MHz, Quasi-Peak

◆ Radiated Disturbance (Electric Field), 150kHz-1GHz, Quasi-Peak; 1GHz-18GHz, Peak/Weighted

◆ Harmonic Current Emission Test, According to IEC 61000-3-2

◆ Voltage Fluctuation and Flicker Test, According to IEC 61000-3-3

 

EMS Test Items

◆ Electrostatic Discharge Immunity, Contact Discharge 6kV, Air Discharge 8kV

◆ Radiated Radio-Frequency Electromagnetic Field Immunity, Maximum Test Field Strength 10V/m

◆ Electrical Fast Transient/Burst Immunity, Maximum Test Level 2kV

◆ Surge Immunity, Maximum Test Level 2kV

◆ Radio-Frequency Conducted Immunity, Maximum Test Level 10V

◆ Power Frequency Magnetic Field Immunity, Maximum Test Field Strength 3A/m

◆ Voltage Dips, Short Interruptions, and Voltage Variations Immunity, According to IEC 61000-4-11


Email:hello@jjrlab.com


Leave Your Message


Write your message here and send it to us


Related News
Read More >>
What is Toy ASTM F963-23 Testing What is Toy ASTM F963-23 Testing
09 .08.2026
Ensure Amazon US toy compliance with ASTM F963-23 testing at JJR Lab. We provide CPSC-accepted lab r...
EN 71-8 Testing Standard for Swings, Slides, and S EN 71-8 Testing Standard for Swings, Slides, and S
09 .08.2026
JJR Lab provides reliable EN 71-8 testing standard services for domestic swings and slides, ensuring...
EN 71-14 Safety Standard for Trampolines for Domes EN 71-14 Safety Standard for Trampolines for Domes
09 .08.2026
Ensure product safety with EN 71-14 testing standards for domestic trampolines. JJR Lab provides exp...
What are the EN 71-13 Toy Safety Requirements? What are the EN 71-13 Toy Safety Requirements?
09 .08.2026
Learn EN 71-13 toy safety requirements for olfactory, cosmetic & gustative toys. JJR LAB provide...
EN 71-12 Safety of N-Nitrosamines and N-Nitrosatab EN 71-12 Safety of N-Nitrosamines and N-Nitrosatab
09 .08.2026
JJR Lab offers expert EN 71-12 testing for N-nitrosamines and N-nitrosatable substances in toys. Ens...
What is the US Toy Standard ASTM F963-17 What is the US Toy Standard ASTM F963-17
09 .07.2026
Ensure US and EU market compliance with ASTM F963-17 and EN 71-11 toy safety testing standards. JJR ...
CPSC Phthalate Testing for Children's Products CPSC Phthalate Testing for Children's Products
09 .07.2026
Ensure US market access with JJR Lab‘s expert CPSC phthalate testing. We apply standard CPSC-CH-C100...
EN 71-3: Safety Standard for Migration of Certain EN 71-3: Safety Standard for Migration of Certain
09 .07.2026
Ensure EU toy safety with expert EN 71-3 testing at JJR LAB. We analyze the migration of 19 heavy me...

Leave Your Message