In product structural design, especially in scenarios involving high temperature, high voltage, circuit transmission, or human contact, the flame retardancy of a product's enclosure is directly related to usage safety, market compliance, and risk prevention. The ul94 flammability rating standard is a core compliance requirement for most product enclosures.
For example, for high-temperature and high-voltage products like electricity meters and connectors that we frequently develop for clients, UL94 certification for the enclosure is a strict mandatory requirement due to their long-term exposure to electrified and heat-generating environments.
ul 94 is currently the most universally applied plastic flammability rating standard globally. Its core focuses on four major indicators: the material's ability to self-extinguish after flame removal, burning time, whether it drips, and whether the drips ignite. If we can thoroughly understand it during our design work, we can avoid potential pitfalls when selecting materials, reading specifications, and conducting certifications.
Ratings are divided into 3 groups based on material types and testing methods. Within each group, a higher rating indicates better flame retardancy:
General Rigid Plastics (Most commonly used): 5VA > 5VB > V-0 > V-1 > V-2 > HB
Foam Plastics: HF-1 > HF-2 > HBF
Films / Sheets: VTM-0 > VTM-1 > VTM-2
Test: The sample is placed horizontally and burned with a flame for 30 seconds.
Criteria:
Thickness 3–13mm: Burning rate ≤40 mm/min
Thickness <3mm: Burning rate ≤70 mm/min
Or the flame self-extinguishes before reaching the 100mm mark.
Characteristics: Only flame retardant, not self-extinguishing, and can continue to burn.
Application: Internal components with no specific fireproof requirements.
Test: The sample is held vertically and ignited twice for 10 seconds each time. It measures:
Single afterflame time (t1, t2)
Total afterflame time for a set of 5 samples
Afterglow time
Whether there are flaming drips and whether those drips ignite the surgical cotton placed below.
Test: 5 ignitions of 5 seconds each + glow wire impact; the test is much more stringent.
5VB: Burn-through is allowed, but it must self-extinguish after flame removal, with no flaming drips igniting the cotton.
5VA: Burn-through is NOT allowed, it must self-extinguish, with no flaming drips igniting the cotton.
Application: Cabinets, large equipment enclosures, and high-safety structural components.
The rules are similar to the V ratings, but the samples are thinner and tested by hanging vertically.
VTM-0 ≈ V-0, VTM-2 ≈ V-2 (Flaming drips are allowed to ignite the cotton).
HF-1: No flaming drips, does not ignite the cotton, and extinguishes quickly after flame removal.
HF-2: A small amount of dripping is allowed, but it does not ignite the cotton.
HBF: Horizontal burning, only burns slowly, and is not self-extinguishing.
For the same material, the thicker it is, the easier it is to pass a higher rating.
Example: If labeled as V-0 (1.5mm) → It only meets the V-0 standard when it is at least 1.5mm thick. If it is thinner, it might only meet V-2.
5VA > 5VB > V-0 > V-1 > V-2 > HB
Commonly used in electronics: V-0 or V-1
Low cost: V-2 / HB
Material: The type of material.
Flame Class: Flammability rating (including the specific thickness).
Example: V-0 (2.0mm) → A thickness of 2.0mm meets the V-0 rating.
UL859 Hair Dryer Test Report Guide
What is UL94 Flammability Testing
Button Cell Battery 16 CFR 1263 + UL 4200A + GCC C
US Marketplace Electric Fan UL507 Testing + TIC Gu
IT/AV Power Supply Export Compliance for South Kor
Power Supply IPX7 Waterproof Testing Service
Power Adapter Export to Thailand Certification
Switching Power Supply / Charger CB Certification
24-hour online customer service at any time to respond, so that you worry!