Brazil ANATEL Mobile Phone Charger Testing Standard Act 5155/2024

Views :
Update time : 2025-09-22

On April 17th, ANATEL issued the new Act 5155, which outlines testing requirements for mobile phone chargers. This new act will come into effect on October 14, 2024, replacing Act 5159.

 

Brazil ANATEL Mobile Phone Charger Testing Standard Act 5155/2024(图1)


Here are the key changes in Act 5155:

1. ESD Levels for Car Chargers  

The new act improves the ESD (electrostatic discharge) requirements for car chargers. Specifically, ESD must now comply with ISO 10605/2008, section 8.3, with contact discharge set at 6kV (removing 2/4kV), and air discharge set at 8kV (removing 4/6kV).

 

2. Streamlined Surge and Transient Immunity Testing  

For car chargers, surge and transient immunity tests must now only be applied to pULses 2a, 3a, and 3b according to ISO 7637-2/2004, with the requirement for pulse 2b removed.

 

3. Safety Testing for Wall Adapters  

The new regulations mandate that safety testing be conducted on 22 adapter samples to ensure a stable evaluation process.

 

4. Size Testing for Wall Adapter Plugs  

Effective from January 1, 2025, adapters must demonstrate compliance with the size specifications in ABNT NBR NM 60884-1/2010, section 9.1 (Plugs and sockets for household and similar purposes) and Annex A of ABNT NBR 14136/2012 (Plugs and sockets for household and similar use in AC currents of 20A/250V). If manufacturers opt for testing under Act 5155, the size requirement will apply to chargers approved before January 1, 2025.

 

5. New Mechanical, Electrical, and Thermal Stress Testing for Wall Adapters  

Adapters must undergo 1,000 connection and disconnection cycles to check for any safety or functional degradation. After the cycles, they must withstand voltage (2000V) to test for leakage current. Chargers must endure mechanical tests, including free-fall, impact, compression, pulling, and wear tests, without safety-degrading damage.

 

6. Updates for Wall Adapters Used with Mobile Phones by October 14th  

All wall adapters for mobile phones must have their CoC updated to comply with the new Act 5155, undergoing new safety tests. Vehicle chargers tested under Act 5159 do not need to be retested during updates.

 

Source:https://sei.anatel.gov.br/sei/modulos/pesquisa/md_pesq_documento_consulta_externa.php?8-74Kn1tDR89f1Q7RjX8EYU46IzCFD26Q9Xx5QNDbqZLU9xv_l8FX5twd-7FgbPjND5G7NSXm7YtX9Gibv3FM-IBO-oSV-IvHWX5qO2qvJ2giDYwQLIIpNT2E0uLj86d

Email:hello@jjrlab.com


Leave Your Message


Write your message here and send it to us


Related News
Read More >>
Cosmetics Registration and Filing in China Cosmetics Registration and Filing in China
03 .24.2026
China defines cosmetics as daily products for cleaning/beauty; needs NMPA filing, safety tests, form...
China Cosmetic Claims Testing Service China Cosmetic Claims Testing Service
03 .24.2026
Title highlights claim compliance: cosmetics must prove safety and efficacy in China. Tests: patch, ...
Chinese Cosmetic Product Testing Laboratories Chinese Cosmetic Product Testing Laboratories
03 .24.2026
China cosmetic filing compliant lab reports covering micro, physico, tox and human tests, with tox e...
Animal Experiment Testing Services for European an Animal Experiment Testing Services for European an
03 .24.2026
JJR supports EU/US device firms with GLP animal tests, selecting human-like models to meet FDA and I...
China Medical Device Animal Laboratory China Medical Device Animal Laboratory
03 .24.2026
Early FDA-style animal trial expertise, JJR LAB offers GLP preclinical testing with imaging, large-a...
How to Test the Biocompatibility of a Material How to Test the Biocompatibility of a Material
03 .23.2026
Test TPE biocompatibility per ISO 10993/GB via cytotoxicity, sensitization, irritation; ensure >7...
Biocompatibility Testing for Dental Materials Biocompatibility Testing for Dental Materials
03 .23.2026
Biocompatibility testing ensures dental material safety via cytotoxicity, sensitization, irritation,...
Where to Test Medical Device Biocompatibility Where to Test Medical Device Biocompatibility
03 .23.2026
JJR LAB delivers CNAS/CMA-certified biocompatibility testing with ISO 10993 compliance, covering cyt...

Leave Your Message