In response to market and consumer concerns about mask quality and safety, as well as the demand for mask exports overseas, China JJR Laboratory has invested over one million USD in advanced mask testing equipment and actively sought recognition from national and international organizations to provide fast, flexible, and professional internationally recognized mask testing services. Today, JJR has obtained dual recognition from the China National Accreditation Service for Conformity Assessment (CNAS) and the International Accreditation Service (IAS), offering mask testing services accredited by the International Laboratory Accreditation Cooperation (ILAC).

 

China JJR Laboratory provides comprehensive international standard testing such as: Australia AS4381: 2015, China YY0469-2011, YY/T0969-2013, and GB15979, European Union EN 14683: 2019+AC: 2019, and the United States ASTM F2100-19, meeting the requirements for mask exports to different countries and registration.

 

ASTM F2100-19 Testing Methods:

- Bacterial Filtration Efficiency (BFE) %:

- Level 1: ≥95

- Level 2: ≥98

- Level 3: ≥98

- Testing Method: ASTM F2101

 

- Particulate Filtration Efficiency (PFE) % @0.1 micron:

- Level 1: ≥95

- Level 2: ≥98

- Level 3: ≥98

- Testing Method: ASTM F2299

 

- Pressure Differential (mmH₂O/cm²):

- Level 1: <5.0

- Level 2: <6.0

- Level 3: <6.0

- Testing Method: EN 14683

 

- Synthetic Blood Penetration Resistance (mmHg):

- Level 1: 80

- Level 2: 120

- Level 3: 160

- Testing Method: ASTM F1862

 

- Flammability Test:

- Level 1: Class 1

- Level 2: Class 1

- Level 3: Class 1

- Testing Method: 16 CFR 1610

 

EN 14683: 2019 Testing Methods:

- Bacterial Filtration Efficiency (BFE) %:

- Level I: ≥95

- Level II: ≥98

- Level IIR: ≥98

- Testing Method: EN 14683

 

- Pressure Differential (Delta P) (Pa/cm²):

- Level I: <40

- Level II: <40

- Level IIR: <60

- Testing Method: EN 14683

 

- Splash Resistance (kPa):

- Level I: Not Required

- Level II: Not Required

- Level IIR: ≥16.0 (120 mmHg)

- Testing Method: EN 14683

 

- Microbial Cleanliness (CFU/g):

- Level I: ≤30

- Level II: ≤30

- Level IIR: ≤30

- Testing Method: EN 14683

 

AS 4381: 2015 Testing Methods:

- Bacterial Filtration Efficiency (BFE) %:

- Level 1: ≥95

- Level 2: ≥98

- Level 3: ≥98

- Testing Method: EN 14683

 

China Mask Certification Testing Laboratory(图1)


- Pressure Differential (mmH₂O/cm²):

- Level 1: <4.0

- Level 2: <5.0

- Level 3: <5.0

- Testing Method: EN 14683

 

- Synthetic Blood Penetration Resistance (mmHg):

- Level 1: 80

- Level 2: 120

- Level 3: 160

- Testing Method: ISO 22609

 

biocompatibility iso 10993 testing Methods:

- Cell Toxicity: iso 10993-5

- Irritation: iso 10993-10

- Skin Sensitization: ISO 10993-10

 

In addition to the above standards, our center also offers various mask tests to meet different market requirements, including:

 

- Viral Filtration Efficiency (VFE) %

- GB 15979 Microbial Indicator Requirements

- Antibacterial Efficiency Testing

- Antiviral Efficiency Testing

 

Mask Testing Equipment:

To meet the large demand for mask testing and to ensure timely reporting, China JJR Laboratory has invested over one million USD in advanced mask testing equipment to immediately improve the mask testing capacity and speed.

 


Email:hello@jjrlab.com


Leave Your Message


Write your message here and send it to us


Related News
Read More >>
CPSC eFiling Process Guide for Amazon Shipments CPSC eFiling Process Guide for Amazon Shipments
06 .17.2026
JJR Lab provides CPSC testing for Amazon shipments under CPC and GCC standards, ensuring smooth eFil...
SAA approval testing services SAA approval testing services
06 .17.2026
JJR Lab provides FCC HAC testing for mobile phones under 47 CFR FCC and ANSI standards, supporting 1...
US FCC 100% Hearing Aid Compatibility (HAC) for Mo US FCC 100% Hearing Aid Compatibility (HAC) for Mo
06 .17.2026
JJR provides FCC HAC testing for mobile phones under 47 CFR FCC rules and ANSI standards, supporting...
Australia Food Contact Testing Australia Food Contact Testing
06 .17.2026
JJR provides Australia food contact testing under FSANZ-related standards, including AS 2070, EU 10/...
ISED RF Testing Services ISED RF Testing Services
06 .16.2026
JJR LAB provides ISED RF and SAR testing for Canada, using ICES-003, RSS series and FCC-aligned EMI ...
CEC Energy Efficiency Compliance Service CEC Energy Efficiency Compliance Service
06 .16.2026
JJR LAB provides CEC compliance testing under California Energy Commission rules using IEC 62087 and...
U.S. DOE Energy Efficiency Compliance Testing Serv U.S. DOE Energy Efficiency Compliance Testing Serv
06 .16.2026
U.S. DOE Energy Efficiency Compliance Testing by JJR Lab. We provide testing and certification suppo...
FDA Compliance Testing for Food Contact Products FDA Compliance Testing for Food Contact Products
06 .16.2026
JJR Lab provides FDA compliance testing for food contact products, covering FDA 21 CFR standards suc...

Leave Your Message