EMC China Lab

Energy Storage Power Supply EMC Testing

Views :
Update time : 2024-12-23

To meet the high-power testing needs of new energy storage products, China’s JJR Laboratory has expanded its high-power testing capabilities, including a 966 electromagnetic anechoic chamber, conducted testing, lightning surge testing, EFT, and more.

 

EU Testing Standards:

- EN IEC 61000-6-1/2 & EN IEC 61000-6-3/4

- EN 62920 (with photovoltaic systems)

- EN IEC 62040-2

- EN IEC 61000-3-2/11 & en 61000-3-3/12

 

International Testing Standards:

- IEC 61000-6-1/2 & IEC 61000-6-3/4

- IEC 62920 (with photovoltaic systems)

- IEC 62040-2

- IEC 61000-3-2/11 & IEC 61000-3-3/12

 

China Testing Standards:

- GB/T 17799.1/2 & GB 17799.3

- GB/T 7260.2

- GB 17625.1 & GB/T 17625.2/7/8

 

Home Energy Storage emc testing

These products primarily target power capacities of 5 kWh, 10 kWh, and 20 kWh (1 kWh = 1 kilowatt-hour). The rated DC input voltage does not exceed 1500 VDC, the rated AC input voltage does not exceed 400 VAC, and both the DC and AC rated input currents do not exceed 200 A.

 

- AC Input Voltage: 0–600 V

- DC Input Voltage: 0–1000 V

- Input Current: 0–100 A

- Input Modes: AC single-phase, AC three-phase, DC power supply

- Test Items: Surge and electrical fast transient burst

 

Equipment Details

1. Device Name: 250 kVA Three-Phase Stabilized Power Supply

 - Output Voltage: AC 0–450 V

 - Output Current: 0–250 A

 - Purpose: Power supply for three-phase laboratory samples

 

2. Device Name: 90 kVA Frequency Converter Power Supply

 - Output Voltage: AC 0–400 V

 - Output Current: 0–250 A

 - Purpose: Power supply for 120 V/60 Hz laboratory samples

 

3. Device Name: PV Power Supply (Three Units)

 - Output Voltage: AC 0–1500 V

 - Output Current: 0–40 A

 - Purpose: Power supply for the photovoltaic interface of energy storage power systems

 

4. Device Name: Power Filter (One Each for Conducted and Radiated Testing)

 - Output Voltage: AC 0–450 V / DC 0–1000 V

 - Output Current: 0–250 A

 - Purpose: FilteRED power supply for laboratory products in conducted and radiated tests

 

3-Meter Radiation Anechoic Chambers (Three Rooms)

- Maximum AC Supply Voltage: 450 V

- Maximum DC Supply Voltage: 1000 V

- Maximum Supply Current: 250 A


Email:hello@jjrlab.com


Leave Your Message


Write your message here and send it to us


Related News
Read More >>
SOR/2016-181 Canada Kettle Reglating SOR/2016-181 Canada Kettle Reglating
09 .16.2025
SOR/2016-181 Canada kettle compliance: Plug-in & non-plug-in must meet CSA C22.1 safety standard...
SOR/2016-181 Canada petl Regulations SOR/2016-181 Canada petl Regulations
09 .16.2025
SOR/2016-181 Canada kettle regulations: plug-in/non-plug-in must comply with CSA 22.2 or C22.2 No.64...
ASTM F1849 Short Track Speed Skating Helmet Testin ASTM F1849 Short Track Speed Skating Helmet Testin
09 .16.2025
ASTM F1849-23 Short Track Speed Skating Helmet Test: labels, retention, projections, impact, vision....
Certificate to Sell Kids Tools in USA Certificate to Sell Kids Tools in USA
09 .16.2025
Guide to selling kids’ tools in the USA: CPC, CPSIA, CPSC & ASTM compliance, labeling, safety te...
Is UL Approval Required in the U.S.? Is UL Approval Required in the U.S.?
09 .16.2025
JJR Lab provides UL testing for U.S. entry—covering batteries, smart home, plugs, IoT, and more—ensu...
REACH Certification vs. Prop 65 REACH Certification vs. Prop 65
09 .16.2025
REACH vs Prop 65: EU & CA rules limit hazardous substances with testing, labeling & scope di...
ASTM F963 Heavy Metal Toys ASTM F963 Heavy Metal Toys
09 .16.2025
ASTM F963 Heavy Metal Toys testing by JJR LAB ensures Amazon compliance, covering safety standards, ...
FCC Part 15 Unintentional Radiators FCC Part 15 Unintentional Radiators
09 .16.2025
JJR LAB provides FCC Part 15 unintentional radiator testing per ANSI C63.4, ensuring Amazon complian...

Leave Your Message