EMC China Lab

Energy Storage Power Supply EMC Testing

Views :
Update time : 2024-12-23

To meet the high-power testing needs of new energy storage products, China’s JJR Laboratory has expanded its high-power testing capabilities, including a 966 electromagnetic anechoic chamber, conducted testing, lightning surge testing, EFT, and more.

 

EU Testing Standards:

- EN IEC 61000-6-1/2 & EN IEC 61000-6-3/4

- EN 62920 (with photovoltaic systems)

- EN IEC 62040-2

- EN IEC 61000-3-2/11 & en 61000-3-3/12

 

International Testing Standards:

- IEC 61000-6-1/2 & IEC 61000-6-3/4

- IEC 62920 (with photovoltaic systems)

- IEC 62040-2

- IEC 61000-3-2/11 & IEC 61000-3-3/12

 

China Testing Standards:

- GB/T 17799.1/2 & GB 17799.3

- GB/T 7260.2

- GB 17625.1 & GB/T 17625.2/7/8

 

Home Energy Storage emc testing

These products primarily target power capacities of 5 kWh, 10 kWh, and 20 kWh (1 kWh = 1 kilowatt-hour). The rated DC input voltage does not exceed 1500 VDC, the rated AC input voltage does not exceed 400 VAC, and both the DC and AC rated input currents do not exceed 200 A.

 

- AC Input Voltage: 0–600 V

- DC Input Voltage: 0–1000 V

- Input Current: 0–100 A

- Input Modes: AC single-phase, AC three-phase, DC power supply

- Test Items: Surge and electrical fast transient burst

 

Equipment Details

1. Device Name: 250 kVA Three-Phase Stabilized Power Supply

 - Output Voltage: AC 0–450 V

 - Output Current: 0–250 A

 - Purpose: Power supply for three-phase laboratory samples

 

2. Device Name: 90 kVA Frequency Converter Power Supply

 - Output Voltage: AC 0–400 V

 - Output Current: 0–250 A

 - Purpose: Power supply for 120 V/60 Hz laboratory samples

 

3. Device Name: PV Power Supply (Three Units)

 - Output Voltage: AC 0–1500 V

 - Output Current: 0–40 A

 - Purpose: Power supply for the photovoltaic interface of energy storage power systems

 

4. Device Name: Power Filter (One Each for Conducted and Radiated Testing)

 - Output Voltage: AC 0–450 V / DC 0–1000 V

 - Output Current: 0–250 A

 - Purpose: FilteRED power supply for laboratory products in conducted and radiated tests

 

3-Meter Radiation Anechoic Chambers (Three Rooms)

- Maximum AC Supply Voltage: 450 V

- Maximum DC Supply Voltage: 1000 V

- Maximum Supply Current: 250 A


Email:hello@jjrlab.com


Leave Your Message


Write your message here and send it to us


Related News
Read More >>
What is the meaning of EMC? What is the meaning of EMC?
10 .30.2025
EMC (Electro Magnetic Compatibility) = EMI + EMS. EMI tests emissions (CE, RE), EMS immunity (ESD, E...
Why EMC Test Is Required? Why EMC Test Is Required?
10 .30.2025
JJR EMC testing ensures EMI/EMS compliance, reliability, and market access. Tests: CE, RE, ESD, surg...
What is the Difference Between EMI and EMC? What is the Difference Between EMI and EMC?
10 .29.2025
EMI = emission interference; EMC = device ability to work without causing/being affected by EMI. JJR...
What is the difference between CE EMC and CE LVD? What is the difference between CE EMC and CE LVD?
10 .29.2025
LVD ensures electrical safety (Directive 2014/35/EU), CE-EMC ensures electromagnetic compatibility (...
What Is the EU WEEE for Electronic and Electrical What Is the EU WEEE for Electronic and Electrical
10 .28.2025
EU WEEE compliance for electronics ensures eco-friendly disposal. JJR Lab offers registration, stand...
What Is the ASTM D4316-95(2016) Hot Water Bottle T What Is the ASTM D4316-95(2016) Hot Water Bottle T
10 .28.2025
JJR Lab provides ASTM D4316-95(2016) hot water bottle testing services, covering material strength, ...
Amazon Electric Massager UL1647 Test Report Amazon Electric Massager UL1647 Test Report
10 .28.2025
JJR offers UL1647 testing for electric massagers and fitness devices, covering electrical safety, me...
What Is IEC 60068-2-5:2018 Solar Radiation Test? What Is IEC 60068-2-5:2018 Solar Radiation Test?
10 .28.2025
IEC 60068-2-5:2018 solar radiation testing ensures outdoor product durability under UV, heat, and su...

Leave Your Message