Physical Packaging Performance Testing Standards

Views :
Update time : 2025-02-07

1. Accelerated Aging (1 year)

- Testing Standard: YY/T 0681.1-2018, ASTM F 1980-16

- Duration: 4 weeks

 

Physical Packaging Performance Testing Standards(图1)


2. Vacuum Leak

- Testing Standard: ASTM D3078-02, GB15171

- Duration: 2 weeks

 

3. Dye Penetration

- Testing Standard: YY/T 0681.4-2010, ASTM F1929-2015

- Duration: 2 weeks

 

4. Seal Peel/Peel Strength

- Testing Standard: YY/T 0681.2-2010, ASTM F88-15

- Duration: 2 weeks

 

5. Microbial Barrier (Wet Method)

- Testing Standard: YY/T 0681.14

- Duration: 2 weeks

 

6. Sterility

- Testing Standard:

 - Chinese Pharmacopoeia 2020 Edition, Part IV, General Chapter (1101) Sterility Test

 - United States Pharmacopeia - National Formulary General Chapter <71> Sterility Test (Effective 2013)

- Duration: 3 weeks

 

7. Appearance (Visual Inspection)

- Testing Standard: YY/T 0681.11-2014, ASTM F1886/F1886M-16

- Duration: 2 weeks

 

8. Burst Test

- Testing Standard: YY/T 0681.3-2016, ASTM F1140/F1140M-13(2020)e1

- Duration: 2 weeks

 

9. Bubble Test

- Testing Standard: YY/T 0681.5-2010, ASTM F 2096-11

- Duration: 2 weeks

 

### Packaging Validation

 

10. Packaging Validation (1 Year, 1 Node, 1 Batch)

- Includes: Accelerated Aging, Vacuum Leak, Dye Penetration, Seal Peel, Microbial Barrier (Wet Method), Sterility, Visual Inspection, Burst, Bubble

- Duration: 8 weeks

 

11. Packaging Validation (1 Year, 2 Nodes, 1 Batch)

- Includes: Accelerated Aging, Vacuum Leak, Dye Penetration, Seal Peel, Microbial Barrier (Wet Method), Sterility, Visual Inspection, Burst, Bubble

- Duration: 8 weeks

 

12. Packaging Validation (1 Year, 2 Nodes, 3 Batches)

- Includes: Accelerated Aging, Vacuum Leak, Dye Penetration, Seal Peel, Microbial Barrier (Wet Method), Sterility, Visual Inspection, Burst, Bubble

- Duration: 8 weeks

 

13. Packaging Validation (2 Years, 1 Node, 1 Batch)

- Includes: Accelerated Aging, Vacuum Leak, Dye Penetration, Seal Peel, Microbial Barrier (Wet Method), Sterility, Visual Inspection, Burst, Bubble

- Duration: 12.5 weeks


Email:hello@jjrlab.com


Leave Your Message


Write your message here and send it to us


Related News
Read More >>
Mandatory Standard for Portable Power Banks GB 473 Mandatory Standard for Portable Power Banks GB 473
04 .12.2026
New mandatory GB 47372-2026 standard strengthens portable power bank safety through stricter cell te...
ISO 10993-10 In Vitro Skin Sensitization Test Serv ISO 10993-10 In Vitro Skin Sensitization Test Serv
04 .11.2026
In vitro skin sensitization tests assess allergic risks for safety use. JJR LAB offers ISO 10993-10 ...
What is ISO 10993 Biocompatibility Testing? What is ISO 10993 Biocompatibility Testing?
04 .11.2026
JJR is a CNAS- and ISO/IEC 17025-accredited Laboratory providing ISO 10993 compliance testing. Repor...
How to Perform a Valid CCK-8 Cytotoxicity Assay How to Perform a Valid CCK-8 Cytotoxicity Assay
04 .10.2026
A valid CCK-8 cytotoxicity assay uses WST-8 to assess cell viability via color change, with key step...
Introduction to Cytotoxicity Assay (CCK-8 Method) Introduction to Cytotoxicity Assay (CCK-8 Method)
04 .10.2026
CCK-8 assay measures viable cells via WST-8 conversion, enabling rapid, sensitive detection for drug...
What Are the Cytotoxicity Assay Methods? What Are the Cytotoxicity Assay Methods?
04 .10.2026
Cytotoxicity assays reveal cell safety by measuring viability or damage. JJR LAB outlines methods li...
What is Ingress Protection (IP) Testing and Standa What is Ingress Protection (IP) Testing and Standa
04 .08.2026
Ingress Protection (IP) defines enclosure resistance to dust and water per IEC 60529; JJR LAB verifi...
What is UL 153 Lighting Standards and Portable Lum What is UL 153 Lighting Standards and Portable Lum
04 .08.2026
UL 153 defines safety rules for portable luminaires; Amazon requires compliant testing. JJR verifies...

Leave Your Message